Spectroscopic measurements and terahertz imaging of the cornea using a rapid scanning terahertz time domain spectrometer |
Wen-Quan Liu(刘文权)1,2,3,4, Yuan-Fu Lu(鲁远甫)1,2,4, Guo-Hua Jiao(焦国华)1,2,4, Xian-Feng Chen(陈险峰)5, Zhi-Sheng Zhou(周志盛)1,2,4, Rong-Bin She(佘荣斌)1,2,4, Jin-Ying Li(李金瑛)6, Si-Hai Chen(陈四海)1,2,4, Yu-Ming Dong (董玉明)1,2,4, Jian-Cheng Lü(吕建成)1,2,4 |
1 Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China;
2 Biomedical Engineering Laboratory for Photoelectric Sensing Technology, Shenzhen 518055, China;
3 Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China;
4 The Chinese University of Hong Kong, Shatin, Hong Kong, China;
5 School of Electronic Engineering, Bangor University, Bangor, Gwynedd LL57 1UT, UK;
6 Department of Ophthalmology, Peking University Shenzhen Hospital, Shenzhen 518036, China |
|
|
Abstract Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy (THz-TDS) system. A voice coil motor stage based optical delay line (VCM-ODL) is developed to provide a rather simple and robust structure with both the high scanning speed and the large delay length. The developed system is used for THz spectroscopic measurements and imaging of the corneal tissue with different amounts of water content, and the measurement results show the consistence with the reported results, in which the measurement time using VCM-ODL is a factor of 360 shorter than the traditional motorized optical delay line (MDL). With reducing the water content a monotonic decrease of the complex permittivity of the cornea is observed. The two-term Debye relaxation model is employed to explain our experimental results, revealing that the fast relaxation time of a dehydrated cornea is much larger than that of a hydrated cornea and its dielectric behavior can be affected by the presence of the biological macromolecules. These results demonstrate that our THz spectrometer may be a promising candidate for tissue hydration sensing and practical application of THz technology.
|
Received: 17 December 2015
Revised: 22 March 2016
Accepted manuscript online:
|
PACS:
|
07.57.Pt
|
(Submillimeter wave, microwave and radiowave spectrometers; magnetic resonance spectrometers, auxiliary equipment, and techniques)
|
|
78.20.Ci
|
(Optical constants (including refractive index, complex dielectric constant, absorption, reflection and transmission coefficients, emissivity))
|
|
87.64.-t
|
(Spectroscopic and microscopic techniques in biophysics and medical physics)
|
|
87.85.Pq
|
(Biomedical imaging)
|
|
Fund: Project supported by the National Natural Science Foundation of China (Grant No. 61205101), the Shenzhen Municipal Research Foundation, China (Grant Nos. GJHZ201404171134305 and JCYJ20140417113130693), and the Marie Curie Actions-International Research Staff Exchange Scheme (IRSES) (Grant No. FP7 PIRSES-2013-612267). |
Corresponding Authors:
Yuan-Fu Lu
E-mail: yf.lu@siat.ac.cn
|
Cite this article:
Wen-Quan Liu(刘文权), Yuan-Fu Lu(鲁远甫), Guo-Hua Jiao(焦国华), Xian-Feng Chen(陈险峰), Zhi-Sheng Zhou(周志盛), Rong-Bin She(佘荣斌), Jin-Ying Li(李金瑛), Si-Hai Chen(陈四海), Yu-Ming Dong (董玉明), Jian-Cheng Lü(吕建成) Spectroscopic measurements and terahertz imaging of the cornea using a rapid scanning terahertz time domain spectrometer 2016 Chin. Phys. B 25 060702
|
[1] |
Jepsen P U, Cooke D G and Koch M 2011 Laser Photon. Rev. 5 124
|
[2] |
Taylor Z D, Garritano J, Shijun S, Bajwa N, Bennett D B, Nowroozi B, Tewari P, Sayre J W, Hubschman J P, Deng S X, Brown E R and Grundfest W S 2015 IEEE Trans. Terahertz Sci. Technol. 5 184
|
[3] |
Taylor Z D, Garritano J, Sung S, Bajwa N, Bennett D B, Nowroozi B, Tewari P, Sayre J, Hubschman J P, Deng S, Brown E R and Grundfest W S 2015 IEEE Trans. Terahertz Sci. Technol. 5 170
|
[4] |
Castro-Camus E, Palomar M and Covarrubias A A 2013 Sci. Rep. 3 2910
|
[5] |
Park S J, Hong J T, Choi S J, Kim H S, Park W K, Han S T, Park J Y, Lee S, Kim D S and Ahn Y H 2014 Sci. Rep. 4 4988
|
[6] |
Oh S J, Kim S H, Jeong K, Park Y, Huh Y M, Son J H and Suh J S 2013 Opt. Express 21 21299
|
[7] |
Dong C, Bao R M, Zhao K, Xu C H, Jin W J and Zhong S X 2014 Chin. Phys. B 23 127802
|
[8] |
Jin W J, Li T, Zhao K and Zhao H 2013 Chin. Phys. B 22 118701
|
[9] |
Zhou Q L, Shi Y L, Zhao D M, Zhang C L, Zhao S Q, Zhao H, Bao R M, Zhu S M, Miao Q, Tian L and Zhao K 2011 Chin. Phys. B 20 010703
|
[10] |
Bennett D, Taylor Z D, Tewari P, Sung S, Maccabi A, Singh R, Culjat M, Grundfest W, Hubschman J P and Brown E 2012 J. Biomed. Opt. 17 097008
|
[11] |
Gabriel C, Sheppard R J and Grant E H 1983 Physics in Medicine and Biology 28 43
|
[12] |
Saviz M and Faraji-Dana R 2013 Prog. Electromag. Res. 137 389
|
[13] |
Klatt G, Gebs R, Schäfer H, Nagel M, Janke C, Bartels A and Dekorsy T 2011 IEEE Sel. Top. Quantum Electron. 17 159
|
[14] |
Yasui T, Saneyoshi E and Araki T 2005 Appl. Phys. Lett. 87 061101
|
[15] |
Wilk R, Hochrein T, Koch M, Mei M and Holzwarth R 2011 J. Opt. Soc. Am. B 28 592
|
[16] |
Yellampalle B, Kim K Y, Rodriguez G, Glownia J H and Taylor A J 2005 Appl. Phys. Lett. 87 211109
|
[17] |
Jin Y S, Jeon S G, Kim G J, Kim J I and Shon C H 2007 Rev. Sci. Instrum. 78 023101
|
[18] |
Kim G J, Jeon SG, Kim J I and Jin Y S 2008 Rev. Sci. Instrum. 79 106102
|
[19] |
Molter D, Ellrich F, Weinland T, George S, Goiran M, Keilmann F, Beigang R and Léotin J 2010 Opt. Express 18 26163
|
[20] |
Xu J Z and Zhang X C 2004 Opt. Lett. 29 2082
|
[21] |
Gente R, Born N, Voβ N, Sannemann W, Léon J, Koch M and Castro-Camus E 2013 J. Infrared Millim. Terahertz Waves 34 316
|
[22] |
Li L, Ma M, Bao B and Chen Q 2011 IEEE Trans. Plasma Sci. 39 127
|
[23] |
Sala K L, Kenney-Wallace G A and Hall G E 1980 IEEE J. Quantum Electron. QE-16 990
|
[24] |
Vieweg N, Rettich F, Deninger A, Roehle H, Dietz R, Gobel T and Schell M 2014 J. Infrared Milli. Terahz Waves 35 823
|
[25] |
Vieweg N, Krumbholz N, Hasek T, Wilk R, Bartels V, Keseberg C, Pethukhov V, Mikulics M, Wetenkamp L and Koch M 2007 Proc. SPIE 6616 66163M
|
[26] |
Liu W Q, Lu Y F, Jiao G H, Chen X F, Li J Y, Chen S H, Dong Y M and Lü J C 2016 Opt. Commum. 359 344
|
[27] |
Thrane L, Jacobsen R H, Jepsen P U and Keiding S R 1995 Chem. Phys. Lett. 240 330
|
[28] |
Pickwell E, Cole B E, Fitzgerald A J, Wallace V P and Pepper M 2004 Appl. Phys. Lett. 84 2190
|
[29] |
Bennett D B, Li W, Taylor Z D, Grundfest W S and Brown E R 2011 IEEE Sensors Journal 11 1253
|
[30] |
Rønne C, Åtrand P O and Keiding S R 1999 Phys. Rev. Lett. 82 2888
|
[31] |
Truong B C, Tuan H D, Kha H H and Nguyen H T 2013 IEEE Trans. Biomed. Eng. 60 1528
|
[32] |
Gabriel S, Lau R W and Gabriel C 1996 Physics in Medicine and Biology 41 2271
|
[33] |
Ronne C and Keiding S R 2002 Journal of Molecular Liquids 101 199
|
[34] |
Federici J F 2012 J. Infrared Millim. Terahertz Waves 33 97
|
[35] |
Xu J, Plaxco K W and Allen S J 2006 J. Chem. Phys. 124 036101
|
[36] |
Holden B O, Mcnally J J and Egan P 1988 Curr. Eye Res. 7 601
|
[37] |
Bennett D B, Taylor Z D, Tewari P, Singh R S, Culjat M O, Grundfest W S, Sassoon D J, Johnson R D, Hubschman J P and Brown E R 2011 J. Biomed. Opt. 16 057003
|
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.