INTERDISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY |
Prev
Next
|
|
|
A modified interval subdividing based geometric calibration method for interior tomography |
Zhang Feng (张峰), Yan Bin (闫镔), Li Lei (李磊), Xi Xiao-Qi (席晓琦), Jiang Hua (江桦) |
National Digital Switching System Engineering & Technology Research Center, Zhengzhou 450002, China |
|
|
Abstract The interior tomography is commonly met in practice, whereas the self-calibration method for geometric parameters remains far from explored. To determine the geometry of interior tomography, a modified interval subdividing based method, which was originally developed by Tan et al.,[11] was presented in this paper. For the self-calibration method, it is necessary to obtain the reconstructed image with only geometric artifacts. Therefore, truncation artifacts reduction is a key problem for the self-calibration method of an interior tomography. In the method, an interior reconstruction algorithm instead of the Feldkamp-Davis-Kress (FDK) algorithm was employed for truncation artifact reduction. Moreover, the concept of a minimum interval was defined as the stop criterion of subdividing to ensure the geometric parameters are determined nicely. The results of numerical simulation demonstrated that our method could provide a solution to the self-calibration for interior tomography while the original interval subdividing based method could not. Furthermore, real data experiment results showed that our method could significantly suppress geometric artifacts and obtain high quality images for interior tomography with less imaging cost and faster speed compared with the traditional geometric calibration method with a dedicated calibration phantom.
|
Received: 20 October 2013
Revised: 23 December 2013
Accepted manuscript online:
|
PACS:
|
87.59.-e
|
(X-ray imaging)
|
|
87.59.bd
|
(Computed radiography)
|
|
Fund: Project supported by the National Basic Research Program of China (Grant No. 2011CB707701), the National High Technology Research and Development Program of China (Grant No. 2012AA011603), and the National Natural Science Foundation of China (Grant Nos. 30970772 and 61372172). |
Corresponding Authors:
Yan Bin
E-mail: wangny@bnu.edu.cn
|
Cite this article:
Zhang Feng (张峰), Yan Bin (闫镔), Li Lei (李磊), Xi Xiao-Qi (席晓琦), Jiang Hua (江桦) A modified interval subdividing based geometric calibration method for interior tomography 2014 Chin. Phys. B 23 098704
|
[1] |
Noo F, Clackdoyle R, Mennessier C, White T A and Roney T J 2000 Phys. Med. Biol. 45 3489
|
[2] |
Smekal V L, Kachelriess M, Stepina E and Kalender W A 2004 Med. Phys. 31 3242
|
[3] |
ChoY, Moseley D J and Siewerdsen J H 2005 Med. Phys. 32 968
|
[4] |
Yang K, Kwan A L C, Miller D F and Boone J M 2006 Med. Phys. 33 1695
|
[5] |
Wu D F, Li L, Zhang L and Xing Y X 2011 Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), October 23-29, 2011 Valencia, Spain, p. 2952
|
[6] |
Brunetti A and Carlo F D 2004 Developments in X-Ray Tomography IV, October 2-6, 2004 Colorado, USA, p. 652
|
[7] |
Panetta D, Belcari N and Guerra A D 2008 Phys. Med. Biol. 53 3841
|
[8] |
Patel V, Chityala R N, Hoffman K R, Ionita C N, Bednarek D R and Rudin S 2009 Med. Phys. 36 48
|
[9] |
Kyriakou Y, Lapp R and Hillebrand L 2008 Phys. Med. Biol. 53 6267
|
[10] |
Kingston A Sakellariou A, Varslot T, Myers G and Sheppard A 2011 Med. Phys. 38 4934
|
[11] |
Tan S Q, Cong P, Liu X M and Wu Z F 2013 NDTE Int. 58 49
|
[12] |
Feldkamp L, Davis L C and Kress J W 1984 J. Opt. Soc. Am. A 1 612
|
[13] |
Sharma K S, Holzner C, Vasilescu D M, Jin X, Narayanan S, Agah M, Hoffman E A, Yu H Y and Wang G 2013 Phys. Med. Biol. 58 4297
|
[14] |
Yu H Y and Wang G 2009 Phys. Med. Biol. 54 2791
|
[15] |
Yang J S, Yu H Y, Jiang M and Wang G 2010 Inverse Probl. 26 35013
|
[16] |
Jin X, Katsevich A, Yu H Y, Wang G, Li L and Chen Z Q 2012 IEEE Trans. Med. Imaging 31 2108
|
[17] |
Dennerlein F 2011 11th International Meeting on Fully Three-dimensional Image Reconstruction in Radiology and Nuclear Medicine, July 11-15, 2011 Potsdam, Germany, p. 80
|
[18] |
Xia Y, Maier A, Dennerlein F, Hofmann H G and Hornegger J 2012 Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), October 27-November 3, 2012 California, USA, p. 2415
|
[19] |
Dennerlein F and Maier A 2012 Medical Imaging 2012: Physics of Medical Imaing, Februray 4-9, 2012 California, USA, p. 83131B
|
[20] |
Xia Y, Maier A and Hofmann H G 2013 Medical Imaging 2013: Physics of Medical Imaging, Februray 9-14, 2013 Florida, USA, p. 86681C
|
[21] |
Wang X C, Yan B, Li L and Hu G E 2012 Chin. Phys. B 21 118702
|
[22] |
Toft P 1996 The Radon Transform, Theory and Implementation (Ph.D. Dissertation) (Copenhagen: Technical University of Denmark)
|
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.