Design of an interventional magnetic resonance imaging coil for cerebral surgery

Xu Yue(许跃), Wang Wen-Tao(王文韬), and Wang Wei-Min(王为民)†
Institute of Quantum Electronics, School of Electronic Engineering and Computer Science, Peking University, Beijing 100871, China
Abstract  In clinical magnetic resonance imaging (MRI), the design of the radiofrequency (RF) coil is very important. For certain applications, the appropriate coil can produce an improved image quality. However, it is difficult to achieve a uniform B1 field and a high signal-to-noise ratio (SNR) simultaneously. In this article, we design an interventional transmitter-and-receiver RF coil for cerebral surgery. This coil adopts a disassembly structure that can be assembled and disassembled repeatedly on the cerebral surgery gantry to reduce the amount of interferences from the MRI during the surgery. The simulation results and the imaging experiments demonstrate that this coil can produce a uniform RF field, a high SNR, and a large imaging range to meet the requirements of the cerebral surgery.
Keywords:  magnetic resonance imaging      Maxwell equation      uniformity      signal-to-noise ratio  
Received:  15 March 2012      Revised:  18 May 2012      Accepted manuscript online: 
PACS:  87.61.-c (Magnetic resonance imaging)  
  87.61.Ff (Instrumentation)  
  84.32.Hh (Inductors and coils; wiring)  
Corresponding Authors:  Wang Wei-Min     E-mail:  wmw@pku.edu.cn

Cite this article: 

Xu Yue(许跃), Wang Wen-Tao(王文韬), and Wang Wei-Min(王为民)† Design of an interventional magnetic resonance imaging coil for cerebral surgery 2012 Chin. Phys. B 21 118704

[1] Blanco R T, Ojala R, Kariniemi J, Perälä J, Niinimäki J and Tervonen O 2005 Eur. J. Radiol. 56 130
[2] Jolesz F A and Blumenfeld S M 1994 Magn. Reson. Q 10 85
[3] Lewin J S, Petersilge C A, Hatem S F, Duerk J L, Lenz G, Clampitt M E, Williams M L, Kaczynski K R, Lanzieri C F, Wise A L and Haaga J R 1998 AJR Am. J. Roentgenol. 170 1593
[4] Ladd S C 2007 C2I2 4 8
[5] Radack D M, Schweitzer M E and Taras J 1997 AJR Am. J. Roentgenol. 169 1649
[6] Mondale K, Dai G, Chu A, Burnham R S and Snyder R E 1999 AJR Am. J. Roentgenol. 172 1581
[7] Barberi E A, Gati J S, Rutt B K and Menon R S 2000 Magn. Reson. Med. 43 284
[8] Amari S, Ulug A, Bormemann J, Zijl P and Barker P 1997 Magn. Reson. Med. 37 243
[9] Shen G, Boada F and Thulborn K 1997 Magn. Reson. Med. 38 717
[10] Leifer M 1997 Magn. Reson. Med. 38 726
[11] Kocharian A, Adkins M C, Amrami K K, McGee K P, Rouleau P A, Wenger D E, Ehman R L and Felmlee J P 2002 Radiology 223 870
[12] Kocharian A, Felmlee J P, McGee K P, Riederer S J and Ehman R L 2000 Magn. Reson. Med. 44 660
[13] Zu D L 2004 Magnetic Resonance Imaging (1st edn.) (Beijing: Higher Education Press) p. 149 (in Chinese)
[14] Firbank M J, Coulthard A, Harrison R M and E D 1999 Phys. Med. Biol. 44 261
[1] Three-dimensional clogging structures of granular spheres near hopper orifice
Jing Yang(杨敬), Dianjinfeng Gong(宫殿锦丰), Xiaoxue Wang(汪晓雪), Zhichao Wang(王志超), Jianqi Li(李建奇), Bingwen Hu(胡炳文), and Chengjie Xia(夏成杰). Chin. Phys. B, 2022, 31(1): 014501.
[2] Signal-to-noise ratio of Raman signal measured by multichannel detectors
Xue-Lu Liu(刘雪璐), Yu-Chen Leng(冷宇辰), Miao-Ling Lin(林妙玲), Xin Cong(从鑫), and Ping-Heng Tan(谭平恒). Chin. Phys. B, 2021, 30(9): 097807.
[3] Time-resolved radial uniformity of pulse-modulated inductively coupled O2/Ar plasmas
Wei Liu(刘巍), Chan Xue(薛婵), Fei Gao(高飞), Yong-Xin Liu(刘永新), You-Nian Wang(王友年), and Yong-Tao Zhao(赵永涛). Chin. Phys. B, 2021, 30(6): 065202.
[4] Blind parameter estimation of pseudo-random binary code-linear frequency modulation signal based on Duffing oscillator at low SNR
Ke Wang(王珂), Xiaopeng Yan(闫晓鹏), Ze Li(李泽), Xinhong Hao(郝新红), and Honghai Yu(于洪海). Chin. Phys. B, 2021, 30(5): 050708.
[5] Novel Woods-Saxon stochastic resonance system for weak signal detection
Yong-Hui Zhou(周永辉), Xue-Mei Xu(许雪梅), Lin-Zi Yin(尹林子), Yi-Peng Ding(丁一鹏), Jia-Feng Ding(丁家峰), Ke-Hui Sun(孙克辉). Chin. Phys. B, 2020, 29(4): 040503.
[6] New embedded DDSCR structure with high holding voltage and high robustness for 12-V applications
Jie-Yu Li(李婕妤), Yang Wang(汪洋)†, Dan-Dan Jia(夹丹丹), Wei-Peng Wei(魏伟鹏), and Peng Dong(董鹏). Chin. Phys. B, 2020, 29(10): 108501.
[7] Noise properties of multi-combination information in x-ray grating-based phase-contrast imaging
Wali Faiz, Ji Li(李冀), Kun Gao(高昆), Zhao Wu(吴朝), Yao-Hu Lei(雷耀虎), Jian-Heng Huang(黄建衡), Pei-Ping Zhu(朱佩平). Chin. Phys. B, 2020, 29(1): 014301.
[8] First polar direct-drive exploding-pusher target experiments on the ShenGuang laser facility
Bo Yu(余波), Jiamin Yang(杨家敏), Tianxuan Huang(黄天晅), Peng Wang(王鹏), Wanli Shang(尚万里), Xiumei Qiao(乔秀梅), Xuewei Deng(邓学伟), Zhanwen Zhang(张占文), Zifeng Song(宋仔峰), Qi Tang(唐琦), Xiaoshi Peng(彭晓世), Jiabin Chen(陈家斌), Yulong Li(理玉龙), Wei Jiang(蒋炜), Yudong Pu(蒲昱东), Ji Yan(晏骥), Zhongjing Chen(陈忠靖), Yunsong Dong(董云松), Wudi Zheng(郑无敌), Feng Wang(王峰), Shaoen Jiang(江少恩), Yongkun Ding(丁永坤), Jian Zheng(郑坚). Chin. Phys. B, 2019, 28(9): 095203.
[9] Uniformity principle of temperature difference field in heat transfer optimization
Xue-Tao Cheng(程雪涛), Xin-Gang Liang(梁新刚). Chin. Phys. B, 2019, 28(6): 064402.
[10] High uniformity and forming-free ZnO-based transparent RRAM with HfOx inserting layer
Shi-Jian Wu(吴仕剑), Fang Wang(王芳), Zhi-Chao Zhang(张志超), Yi Li(李毅), Ye-Mei Han(韩叶梅), Zheng-Chun Yang(杨正春), Jin-Shi Zhao(赵金石), Kai-Liang Zhang(张楷亮). Chin. Phys. B, 2018, 27(8): 087701.
[11] Design of small-scale gradient coils in magnetic resonance imaging by using the topology optimization method
Hui Pan(潘辉), Feng Jia(贾峰), Zhen-Yu Liu(刘震宇), Maxim Zaitsev, Juergen Hennig, Jan G Korvink. Chin. Phys. B, 2018, 27(5): 050201.
[12] Optimization of pick-up coils for weakly damped SQUID gradiometers
Kang Yang(杨康), Jialei Wang(王佳磊), Xiangyan Kong(孔祥燕), Ruihu Yang(杨瑞虎), Hua Chen(陈桦). Chin. Phys. B, 2018, 27(5): 050701.
[13] Implication of two-coupled tri-stable stochastic resonance in weak signal detection
Quan-Quan Li(李泉泉), Xue-Mei Xu(许雪梅), Lin-Zi Yin(尹林子), Yi-Peng Ding(丁一鹏), Jia-Feng Ding(丁家峰), Ke-Hui Sun(孙克辉). Chin. Phys. B, 2018, 27(3): 034203.
[14] Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments
Bo Li(李波), Hui Dong(董慧), Xiao-Lei Huang(黄小磊), Yang Qiu(邱阳), Quan Tao(陶泉), Jian-Ming Zhu(朱建明). Chin. Phys. B, 2018, 27(2): 020701.
[15] Noise analysis of grating-based x-ray differential phase-contrast imaging with angular signal radiography
Wali Faiz, Yuan Bao(鲍园), Kun Gao(高昆), Zhao Wu(吴朝), Chen-Xi Wei(卫晨希), Gui-Bin Zan(昝贵彬), Pei-Ping Zhu(朱佩平), Yang-Chao Tian(田扬超). Chin. Phys. B, 2017, 26(4): 040602.
No Suggested Reading articles found!