Please wait a minute...
Chin. Phys. B, 2018, Vol. 27(5): 058702    DOI: 10.1088/1674-1056/27/5/058702
INTERDISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY Prev   Next  

Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging

Zheng Xu(徐征)1, Xiang Li(李想)1, Pan Guo(郭盼)2, Jia-Min Wu(吴嘉敏)1
1 State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China;
2 School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing 401331, China
Abstract  

The conventional magnetic resonance imaging (MRI) equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure. In order to realize the mobile MRI, this study focuses on the design of gradient coil of unilateral magnet. The unilateral MRI system is used to image the local area above the magnet. The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils, because the region of interest (ROI) and the wiring area of the unilateral magnet are both cylindrical side arc surfaces. Therefore, the equivalent magnetic dipole method is used to design the gradient coil, and the algorithm is improved for the special case of the wiring area and the ROI, so the X and Y gradient coils are designed. Finally, a flexible printed circuit board (PCB) is used to fabricate the gradient coil, and the magnetic field distribution of the ROI is measured by a Gauss meter, and the measured results match with the simulation results. The gradient linearities of x and y coils are 2.82% and 3.56%, respectively, less than 5% of the commercial gradient coil requirement.

Keywords:  unilateral MRI      equivalent magnetic dipole method      gradient coil      current density distribution  
Received:  15 December 2017      Revised:  01 February 2018      Accepted manuscript online: 
PACS:  87.61.-c (Magnetic resonance imaging)  
  84.32.Hh (Inductors and coils; wiring)  
  02.30.Zz (Inverse problems)  
Fund: 

Project supported by the National Natural Science Foundation of China (Grant Nos.51677008,51377182,51707028,and 11647098),the Fundamental Research Funds of the Central Universities,China (Grant No.106112017CDJQJ158834),and the State Key Development Program for Basic Research of China (Grant No.2014CB541602).

Corresponding Authors:  Zheng Xu, Pan Guo     E-mail:  xuzheng@cqu.edu.cn;guopan@cqnu.edu.cn

Cite this article: 

Zheng Xu(徐征), Xiang Li(李想), Pan Guo(郭盼), Jia-Min Wu(吴嘉敏) Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging 2018 Chin. Phys. B 27 058702

[1] Blümich B 1988 Angew. Chem. Int. Ed. 27 195
[2] Callaghan P T 1992 Z. Phys. Chem. 176 132
[3] Xu Z, Meng K K and Cheng J Y 2015 Int. J. Appl. Elec. & Mech. 47 777
[4] Xu Z, Cui X J and Meng K K and Xia YF 2016 IEEE Sens. J. 16 1168
[5] He Z H and He W 2016 Appl. Magn. Reson. 47 1
[6] He Z H, He W, Wu J M and Xu Z 2017 Sensors 17 526
[7] Casanova F and Blümich B 2003 J. Magn. Reson. 163 38
[8] Turner R 1993 Magn. Reson. Imag 11 903
[9] Garrett M W 1951 J. Appl. Phys. 22 1091
[10] Schenck J F, Hussain M A and Edelstein W A (U.S. Patent) 4646024[1983-11-2]
[11] Brideson M A, Forbes L K and Crozier S 2001 John Wiley and Sons Ltd. 14 9
[12] Turner R 1986 J. Phys. D:Appl. Phys. 19 147
[13] Wang L Q and Wang W M 2014 Chin. Phys. B 23 589
[14] Liu W T, Zu D L and Tang X 2010 Chin. Phys. B 19 018701
[15] Lopez H S, Liu F, Poole M and Crozier S 2009 IEEE Trans. Magn. 45 767
[16] Lopez H S, Poole M and Crozier S 2009 J. Magn. Reson. 199 48
[17] Liu W T, Casanova F and Blumich B 2012 Appl. Magn. Reson. 42 101
[18] Xu Y J, Chen Q Y, Zhang G C, Pei Z and Yang X 2015 Appl. Magn. Reson. 46 823
[1] Design of small-scale gradient coils in magnetic resonance imaging by using the topology optimization method
Hui Pan(潘辉), Feng Jia(贾峰), Zhen-Yu Liu(刘震宇), Maxim Zaitsev, Juergen Hennig, Jan G Korvink. Chin. Phys. B, 2018, 27(5): 050201.
[2] Shim coil design for Halbach magnet by equivalent magnetic dipole method
Jia-Min Wu(吴嘉敏), Zheng Xu(徐征), Pan Guo(郭盼), Jin-Feng Qi(戚金凤), Yu-Cheng He(贺玉成). Chin. Phys. B, 2018, 27(10): 104101.
[3] Multi-objective optimization of gradient coil for benchtop magnetic resonance imaging system with high-resolution
Wang Long-Qing (王龙庆), Wang Wei-Min (王为民). Chin. Phys. B, 2014, 23(2): 028703.
[4] Numerical simulation and experimental validation of direct current air corona discharge under atmospheric pressure
Liu Xing-Hua(刘兴华), He Wei(何为), Yang Fan(杨帆), Wang Hong-Yu(王虹宇), Liao Rui-Jin(廖瑞金), and Xiao Han-Guang(肖汉光) . Chin. Phys. B, 2012, 21(7): 075201.
No Suggested Reading articles found!