ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS |
Prev
Next
|
|
|
Retinal axial focusing and multi-layer imaging with a liquid crystal adaptive optics camera |
Liu Rui-Xue (刘瑞雪)a b, Zheng Xian-Liang (郑贤良)a b c, Li Da-Yu (李大禹)a, Xia Ming-Liang (夏明亮)c, Hu Li-Fa (胡立发)a, Cao Zhao-Liang (曹召良)a, Mu Quan-Quan (穆全全)a, Xuan Li (宣丽)a |
a State Key Lab of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China; b University of Chinese Academy of Sciences, Beijing 100049, China; c Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China |
|
|
Abstract With the help of adaptive optics (AO) technology, cellular level imaging of living human retina can be achieved. Aiming to reduce distressing feelings and to avoid potential drug induced diseases, we attempted to image retina with dilated pupil and froze accommodation without drugs. An optimized liquid crystal adaptive optics camera was adopted for retinal imaging. A novel eye stared system was used for stimulating accommodation and fixating imaging area. Illumination sources and imaging camera kept linkage for focusing and imaging different layers. Four subjects with diverse degree of myopia were imaged. Based on the optical properties of the human eye, the eye stared system reduced the defocus to less than the typical ocular depth of focus. In this way, the illumination light can be projected on certain retina layer precisely. Since that the defocus had been compensated by the eye stared system, the adopted 512×512 liquid crystal spatial light modulator (LC-SLM) corrector provided the crucial spatial fidelity to fully compensate high-order aberrations. The Strehl ratio of a subject with -8 diopter myopia was improved to 0.78, which was nearly close to diffraction-limited imaging. By finely adjusting the axial displacement of illumination sources and imaging camera, cone photoreceptors, blood vessels and nerve fiber layer were clearly imaged successfully.
|
Received: 09 December 2013
Revised: 10 February 2014
Accepted manuscript online:
|
PACS:
|
42.70.Df
|
(Liquid crystals)
|
|
42.68.Wt
|
(Remote sensing; LIDAR and adaptive systems)
|
|
42.66.Ew
|
(Physiology of eye; optic-nerve structure and function)
|
|
Fund: Project supported by the National Natural Science Foundation of China (Grant Nos. 60736042, 1174274, and 1174279) and the Plan for Scientific and Technology Development of Suzhou, China (Grant No. ZXS201001). |
Corresponding Authors:
Xuan Li
E-mail: xuanli@ciomp.ac.cn
|
Cite this article:
Liu Rui-Xue (刘瑞雪), Zheng Xian-Liang (郑贤良), Li Da-Yu (李大禹), Xia Ming-Liang (夏明亮), Hu Li-Fa (胡立发), Cao Zhao-Liang (曹召良), Mu Quan-Quan (穆全全), Xuan Li (宣丽) Retinal axial focusing and multi-layer imaging with a liquid crystal adaptive optics camera 2014 Chin. Phys. B 23 094211
|
[1] |
Kitaguchi Y, Fujikado T, Bessho K, Sakaguchi H, Gomi F, Yamaguchi T, Nakazawa N, Mihashi T, and Tano Y 2008 Ophthalmology 115 1771
|
[2] |
Zhong Z, Petrig B L, Qi X and Burns S A 2008 Opt. Express 16 12746
|
[3] |
Martin J A and Roorda A 2005 Ophthalmology 112 2219
|
[4] |
Duncan J L, Talcott K E, Ratnam K, Sundquist S M, Lucero A S, Day S, Zhang Y and Roorda A 2011 Invest. Ophthalmol. Vis. Sci. 52 1557
|
[5] |
Liang J, Williams D R and Miller D T 1997 J. Opt. Soc. Am. 14 2884
|
[6] |
Doble N, Miller D T, Yoon G and Williams D R 2007 Appl. Opt. 46 4501
|
[7] |
Roorda A and Williams D R 1999 Nature 397 520
|
[8] |
Zang Z G, Minato T, Navaretti P, Hinokuma Y, Duelk M, Velez C and Hamamoto K 2010 IEEE Photonics Technology Letters 22 721
|
[9] |
Zang Z G, Mukai K, Navaretti P, Duelk M, Velez C and Hamamoto K 2012 Appl. Phys. Lett. 100 031108
|
[10] |
Zang Z G, Mukai K, Navaretti P, Duelk M, Velez C and Hamamoto K 2011 IEEE Trans. Electron. E94c 862
|
[11] |
Dreher A W, Bille J F and Weinreb R N 1989 Appl. Opt. 28 804
|
[12] |
Doble N, Yoon G, Chen L, Bierden P, Singer B, Olivier S and Williams D R 2002 Opt. Lett. 27 1537
|
[13] |
Zhang Y, Poonja S and Roorda A 2006 Opt. Lett. 31 1268
|
[14] |
Hammer D X, Ferguson R D, Bigelow C E, Iftimia N V, Ustun T E and Burns S A 2006 Opt. Express 14 3354
|
[15] |
Grieve K, Tiruveedhula P, Zhang Y and Roorda A 2006 Opt. Express 14 12230
|
[16] |
Thibos L N and Bradley A 1997 Optom. Vis. Sci. 74 581
|
[17] |
Vargas-Martin F, Prieto P M and Artal P 1998 J. Opt. Soc. Am. A 15 2552
|
[18] |
Mu Q, Cao Z, Li D, Hu L and Xuan L 2007 Opt. Express 15 1946
|
[19] |
Liu C, Mu Q Q, Hu L F, Cao Z L and Xuan L 2010 Chin. Phys. B 19 064214
|
[20] |
Liu R, Qi Y, Zheng X, Xia M and Xuan L 2013 Photon. Res. 1 124
|
[21] |
Peng Z, Liu Y, Yao L, Cao Z, Mu Q, Hu L, Lu X, Xuan L and Zhang Z 2011 Chin. Phys. Lett. 28 094207
|
[22] |
Dai Q, Li Y, Wu R N, Geng Y, Quan W, Li Y Q, Peng Z H and Yao L S 2013 Acta Phys. Sin. 62 044219 (in Chinese)
|
[23] |
Zou Z F, Yao L S, Tang X Z, Ji X J and Xuan L 2008 Chin. Phys. Lett. 25 2524
|
[24] |
Liu Y J, Sun W M, Liu X Q, Yao L S, Lu X H and Xuan L 2012 Acta Phys. Sin. 61 114211 (in Chinese)
|
[25] |
Tang X Z, Peng Z H, Liu Y G, Lu X H and Xuan L 2010 Acta Phys. Sin. 59 6261 (in Chinese)
|
[26] |
Tang X Z, Lu X H, Peng Z H, Liu Y G and Xuan L 2010 Acta Phys. Sin. 59 4001 (in Chinese)
|
[27] |
Tian Y, Pan X, Wang C S, Zhang X Q and Zeng Y 2009 Acta Phys. Sin. 58 6979 (in Chinese)
|
[28] |
Cao Z L, Mu Q Q, Hu L F, Liu Y G and Xuan L 2007 Chin. Phys. 16 1665
|
[29] |
Lu R B, Xu K S, Zhang S Y, Gu X, Xing Z J, Deng H H, Gu J H, Xiao Z D and Lu Z H 1999 Chin. Phys. 8 670
|
[30] |
Li C, Xia M, Li D, Mu Q and Xuan L 2010 J. Biomed. Opt. 15 046009
|
[31] |
Kong N, Li C, Xia M, Li D, Qi Y and Xuan L 2012 J. Biomed. Opt. 17 026001
|
[32] |
Jiang B G, Cao Z L, Mu Q Q, Hu L F, Li C and Xuan L 2008 Chin. Phys. B 17 4529
|
[33] |
Liu R, Li D, Xia M, Kong N, Qi Y, Zheng X and Xuan L 2011 2nd International Symposium on Bioelectronics and Bioinformatics, November 3-5, 2011 Suzhou, China, p. 135
|
[34] |
Takeno K and Shirai T 2012 Opt. Commun. 285 2967
|
[35] |
Liu X A, Zhang J A, Wu L Y and Gan Y 2011 Chin. Phys. B 20 024211
|
[36] |
Ma J, Zheng Z G, Liu Y G and Xuan L 2011 Chin. Phys. B 20 024212
|
[37] |
Thibos L N, Hong X, Bradley A and Cheng X 2002 J. Opt. Soc. Am. A 19 2329
|
[38] |
Sawides L, Gambra E, Pascual D, Dorronsoro C and Marcos S 2010 J. Vis. 10 19
|
[39] |
Merino D, Dainty C, Bradu A and Podoleanu A G 2006 Opt. Express 14 3345
|
[40] |
Sulai Y N and Dubra A 2012 Biomed. Opt. Express 3 1647
|
[41] |
Institute A N S 2007 American National Standard for the Safe Use of Lasers (Orlando, FL: Laser Institute of America)
|
[42] |
Wang B and Ciuffreda K J 2006 Surv. Ophthalmol. 51 75
|
[43] |
Atchison D A and Smith G 2005 J. Opt. Soc. Am. A 22 29
|
[44] |
Ciuffreda K J 1991 Optom. Vis. Sci. 68 243
|
[45] |
Hennessy R T, Iida T, Shina K and Leibowitz H W 1976 Vision Res. 16 587
|
[46] |
Johnson C A 1976 J. Opt. Soc. Am. 66 138
|
[47] |
Klein S A 1998 J. Opt. Soc. Am. A 15 2580
|
[48] |
Goss D A and Grosvenor T 1996 J. Am. Optom. Assoc. 67 619
|
[49] |
Miller D, Thibos L and Hong X 2005 Opt. Express 13 275
|
[50] |
Yellott J I 1982 Vision Res. 22 1205
|
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.
View more on Altmetrics
|
|
|