PHYSICS OF GASES, PLASMAS, AND ELECTRIC DISCHARGES |
Prev
Next
|
|
|
Practical 2.45-GHz microwave-driven Cs-free H- ion source developed at Peking University |
Tao Zhang(张滔), Shi-Xiang Peng(彭士香), Wen-Bin Wu(武文斌), Hai-Tao Ren(任海涛), Jing-Feng Zhang(张景丰), Jia-Mei Wen(温佳美), Teng-Hao Ma(马腾昊), Yao-Xiang Jiang(蒋耀湘), Jiang Sun(孙江), Zhi-Yu Guo(郭之虞), Jia-Er Chen(陈佳洱) |
SKLNPT & IHIP, School of Physics, Peking University, Beijing 100871, China |
|
|
Abstract A practical 2.45-GHz microwave-driven Cs-free H- source was improved based on the experimental H- source at Peking University (PKU). Several structural improvements were implemented to meet the practical requirements of Xi'an Proton Application Facility (XiPaf). Firstly, the plasma chamber size was optimized to enhance the plasma intensity and stability. Secondly, the filter magnetic field and electron deflecting magnetic field were enhanced to reduce co-extracted electrons. Thirdly, a new two-electrode extraction system with farther electrode gap and enhanced water cooling ability to diminish spark and sputter during beam extraction was applied. At last, the direct H- current measuring method was adopted by the arrangement of a new pair of bending magnets before Faraday cup (FC) to remove residual electrons. With these improvements, electron cyclotron resonance (ECR) magnetic field optimization experiments and operation parameter variation experiments were carried out on the H- ion source and a maximum 8.5-mA pure H- beam was extracted at 50 kV with the time structure of 100 Hz/0.3 ms. The root-mean-square (RMS) emittance of the beam is 0.25π·mm·mrad. This improved H- source and extraction system were maintenance-free for more than 200 hours in operation.
|
Received: 06 March 2018
Revised: 08 June 2018
Accepted manuscript online:
|
PACS:
|
52.50.Sw
|
(Plasma heating by microwaves; ECR, LH, collisional heating)
|
|
52.50.Dg
|
(Plasma sources)
|
|
52.27.Cm
|
(Multicomponent and negative-ion plasmas)
|
|
52.77.-j
|
(Plasma applications)
|
|
Fund: Project supported by the National Natural Science Foundation of China (Grant Nos. 11775007 and 11575013). |
Corresponding Authors:
Shi-Xiang Peng
E-mail: sxpeng@pku.edu.cn
|
Cite this article:
Tao Zhang(张滔), Shi-Xiang Peng(彭士香), Wen-Bin Wu(武文斌), Hai-Tao Ren(任海涛), Jing-Feng Zhang(张景丰), Jia-Mei Wen(温佳美), Teng-Hao Ma(马腾昊), Yao-Xiang Jiang(蒋耀湘), Jiang Sun(孙江), Zhi-Yu Guo(郭之虞), Jia-Er Chen(陈佳洱) Practical 2.45-GHz microwave-driven Cs-free H- ion source developed at Peking University 2018 Chin. Phys. B 27 105208
|
[1] |
Welton R F, Dudnikov V G, Gawne K R, Han B X, Murray S N, Pennisi T R, Roseberry R T, Santana M, Stockli M P and Turvey M W 2012 Rev. Sci. Instrum. 83 02A725
|
[2] |
Hemsworth R S and Inoue T 2005 IEEE Trans. Plasma Sci. 33 1799
|
[3] |
Li G R, Guan X L, Zheng S X, Wang X W, Yao H J, Yang Z, Huang W H and Lee S Y 2014 The 12th Symposium on Accelerator Physics, August 15, 2014, Lanzhou University, China
|
[4] |
Zhang T, Peng S X, Ren H T, Xu Y, Zhang A L, Zhang J F, Zhao J, Guo Z Y and Chen J E 2014 Proceedings of LINAC2014, August 2014, Geneva, Switzerland, THPP115
|
[5] |
Bacal M 2006 Nucl. Fusion 46 S250
|
[6] |
Hall R I, Cadez I, Landau M, Pichou F and Scherman C 1988 Phys. Rev. Lett. 60 337
|
[7] |
Peng S X, Lu P N, Ren H T, Zhao J, Xu Y, Guo Z Y, Yuan Z X and Chen J E 2012 Proceedings of IBIC2012 October 1-4, 2012, Tsukuba, Japan, TUPB64
|
[8] |
Geller R 1996 Electron Cyclotron Resonance Ion Sources and ECR Plasmas (Bristol:Institute of Physics) p. 332
|
[9] |
Wu W B, Ren H T, Peng S X, Xu Y, Wen J M, Zhang T, Zhang J F, Zhang A L, Sun J, Guo Z Y and Chen J E 2018 Sci. Chin.-Phys. Mech. Astron. 61 045211
|
[10] |
Paunska Ts, Schlüter H, Shivarova A and Tarnev Kh 2006 Phys. Plasma S 13 023504
|
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.