Abstract  

As the aqueous humor leaves the eye, it first passes through the trabecular meshwork (TM). Increased flow resistance in this region causes elevation of intraocular pressure (IOP), which leads to the occurrence of glaucoma. To quantitatively evaluate the effect of high IOP on the configuration and hydraulic permeability of the TM, second harmonic generation (SHG) microscopy was used to image the microstructures of the TM and adjacent tissues in control (normal) and high IOP conditions. Enucleated rabbit eyes were perfused at a pressure of 60 mmHg to achieve the high IOP. Through the anterior chamber of the eye, in situ images were obtained from different depths beneath the surface of the TM. Porosity and specific surface area of the TM in control and high IOP conditions were then calculated to estimate the effect of the high pressure on the permeability of tissue in different depths. We further photographed the histological sections of the TM and compared the in situ images. The following results were obtained in the control condition, where the region of depth was less than 55 μ with crossed branching beams and large pores in the superficial TM. The deeper meshwork is a silk-like tissue with abundant fluorescence separating the small size of pores. The total thickness of pathway tissues composed of TM and juxtacanalicular (JCT) is more than 100 μ. After putting a high pressure on the inner wall of the eye, the TM region progressively collapses and decreases to be less than 40 μ. Fibers of the TM became dense, and the porosity at 34 μ in the high IOP condition is comparable to that at 105 μ in the control condition. As a consequent result, the permeability of the superficial TM decreases rapidly from 120 μm2 to 49.6 μm2 and that of deeper TM decreases from 1.66 μm2 to 0.57 μm2. Heterogeneity reflected by descent in permeability reduces from 12.4 μ of the control condition to 3.74 μ of the high IOP condition. The persistently high IOP makes the TM region collapse from its normal state, in which the collagen fibers of the TM are arranged in regular to maintain the physiological permeability of the outflow pathway. In the scope of pathologically high IOP, the microstructure of the TM is sensitive to pressure and hydraulic permeability can be significantly affected by IOP.

Keywords:  trabecular meshwork      hydraulic permeability      intraocular pressure      glaucoma  
Received:  19 October 2014      Revised:  14 December 2014      Accepted manuscript online: 
PACS:  87.64.mn (Multiphoton)  
  42.66.-p (Physiological optics)  
  87.85.G- (Biomechanics)  
Fund: 

Project Project for Academic Human Resources Development in Institutions of Higher Learning under the Jurisdiction of Beijing Municipality, China (Grant No. PHR201110506).

Corresponding Authors:  Zheng Wei, Liu Zhi-Cheng     E-mail:  zhengwei@siat.ac.cn;zcliu@ccmu.edu.cn
About author:  87.64.mn; 42.66.-p; 87.85.G-

Cite this article: 

Mei Xi (梅曦), Ren Lin (任琳), Xu Qiang (许强), Zheng Wei (郑炜), Liu Zhi-Cheng (刘志成) Effect of persistent high intraocular pressure on microstructure and hydraulic permeability of trabecular meshwork 2015 Chin. Phys. B 24 058701

[1] Seiler T and Wollensak J 1985 Arch. Clin. Exp. Ophthalmol. 223 88
[2] Last J A, Pan T, Ding Y, Reilly C M, Keller K, Acott T S, Fautsch M P, Murphy C J and Russell P 2011 Invest. Ophthalmol. Vis. Sci. 52 2147
[3] Camras L J, Stamer W D, Epstein D, Gonzalez P and Yuan F 2014 Invest. Ophthalmol. Vis. Sci. 55 814
[4] Maëpea O and Bill A 1992 Exp. Eye. Res. 54 879
[5] Maëpea O and Bill A 1989 Exp. Eye. Res. 49 645
[6] Battista S A, Lu Z, Hofmann S, Freddo T, Overby D R and Gong H 2008 Invest. Ophthalmol. Vis. Sci. 49 5346
[7] Stamer W D and Acott T S 2012 Curr. Opin. Ophthalmol. 23 135
[8] Hann C R, Bahler C K and Johnson D H 2005 Invest. Ophthalmol. Vis. Sci. 46 1
[9] Grant W M 1963 Arch. Ophthalmol. 69 783
[10] Rosenquist R, Epstein D, Melamed S, Johnson M and Grant W M 1990 Curr. Eye. Res. 8 1233
[11] Kagemann L, Wollstein G, Ishikawa H, Bilonick R A, Brennen P M, Folio L S, Gabriele M L and Schuman J S 2010 Invest. Ophthalmol. Vis. Sci. 51 4054
[12] Leung C K and Weinreb R N 2011 Eye 25 261
[13] Irshad F A, Mayfield M S, Zurakowski D and Ayyala R S 2010 Ophthalmology 117 916
[14] Lu J, Li H, He Y, Shi G and Zhang Y 2011 Acta Phys. Sin. 60 034207 (in Chinese)
[15] Zoumi A, Yeh A and Tromberg B J 2002 Proc. Natl. Acad. Sci. USA 99 11014
[16] Ammar D A, Lei T C, Gibson E A and Kahook M Y 2010 Molecular Vision 16 935
[17] Gonzalez J M Jr, Heur M and Tan J C 2012 Invest. Ophthalmol. Vis. Sci. 53 3395
[18] Ye T C and Wang N L 2007 The Atlas of Clinical Glaucoma (Beijing: People's Medical Publishing House)
[19] Li D, Zheng W and Qu J Y 2009 Opt. Lett. 34 202
[20] Overby D, Ruberti J, Gong H, Freddo T F and Johnson M 2001 J. Biomech. Eng. 123 154
[21] Fautsch M P and Johnson D H 2006 Invest. Ophthalmol. Vis. Sci. 47 4181
[22] Johnson M 2006 Exp. Eye. Res. 82 545
[23] Gong H, Ruberti J, Overby D, Johnson M and Freddo T F 2002 Exp. Eye. Res. 75 347
[24] Wang X, Lin L, Chang S, Zhang H and Hao S 2008 Chin. Phys. Lett. 25 2844
[25] Hann C R, Bentley M D, Vercnocke A, Ritman E L and Fautsch M P 2011 Exp. Eye. Res. 92 104
[26] Stamer W D 2012 Invest. Ophthalmol. Vis. Sci. 53 2470
[27] Weinbaum S 1997 Ann. Biomed. Eng. 26 627
[1] Laser-assisted XUV double ionization of helium atoms: Intensity dependence of joint angular distributions
Fengzheng Zhu(朱风筝), Genliang Li(黎根亮), Aihua Liu(刘爱华). Chin. Phys. B, 2020, 29(7): 073202.
No Suggested Reading articles found!