Please wait a minute...
Chin. Phys. B, 2012, Vol. 21(6): 064213    DOI: 10.1088/1674-1056/21/6/064213
ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS Prev   Next  

Application of a characterized difference-frequency laser source to carbon monoxide trace detection

Alireza Khorsandi, Zahra Shabani, Monireh Ranjbar, and S. Ali Hoseinzadeh Salati
Department of Physics, University of Isfahan, 81746-73441 Isfahan, Iran
Abstract  A tunable continuous wave (cw) mid-infrared (MIR) laser based on difference-frequency generation (DFG) in a 1.5-cm long AgGaS2 nonlinear crystal for trace gas detection is reported. Two visible and near-infrared diode lasers were used as pump and signal sources. The MIR-DFG laser was tunable in a wavelength range of 4.75 μm-4.88 μm. The phase-matching (PM) condition was non-critically achieved by adjusting the temperature of the crystal for fixed pairs of input pump and signal wavelengths. The required PM temperatures of the generated MIR-DFG wavelengths have been calculated by using three sets of recent Sellmeier equations and the temperature-dispersion equations of AgGaS2 given by Willer U, et al. (Willer U, Blanke T and Schade W 2001 Appl. Opt. 40 5439). Then the calculated PM temperatures are compared with the experimental values. The performance of the MIR-DFG laser is shown by the trace detection of the P(16) carbon monoxide (12C16O) absorption line in a laboratory-fabricated absorption cell. The enhanced sensitivity of about 0.6 × 10-4 was obtained through the long path absorption provided by consecutive reflections between coated cylindrical mirrors of a constructed cell.
Keywords:  difference-frequency generation      AgGaS2 crystal      multi-pass cell  
Received:  24 October 2011      Revised:  10 December 2011      Accepted manuscript online: 
PACS:  42.62.Fi (Laser spectroscopy)  
  42.65.-k (Nonlinear optics)  
Corresponding Authors:  Alireza Khorsandi     E-mail:  a.khorsandi@phys.ui.ac.ir

Cite this article: 

Alireza Khorsandi, Zahra Shabani, Monireh Ranjbar, and S. Ali Hoseinzadeh Salati Application of a characterized difference-frequency laser source to carbon monoxide trace detection 2012 Chin. Phys. B 21 064213

[1] Wondraczek L, Khorsandi A, Willer U, Heide G, Schade W and Heinz Frischat G 2004 Combust. Flame. 138 30
[2] Richter D, Fried A and Weibring P 2009 Laser & Photon. Rev. 3 343
[3] Tittel F K, Richter D and Fried A 2003 Topics Appl. Phys. 89 445
[4] Sharpe S W, Kelly J F, Hartman J S, Gmachl C, Capasso F, Sivco D L, Baillargeon J N and Cho A Y 1998 Opt. Lett. 23 1396
[5] Brandt C, Matrosov V N, Petermann K and Huber G 2011 Advanced Solid-State Photonics, OSA Technical Digest (CD), paper AMB15
[6] Petersen E B, Shi W, Chavez-Pirson A, Peyghambarian N and Cooney A T 2011 Appl. Phys. Lett. 98 121119
[7] Jiang Y, Li D, Ding Y J and Zotova I B 2011 Opt. Lett. 36 1608
[8] Shi W, Ding Y J and Schunemann P G 2004 Opt. Commun. 233 183
[9] Ahlawat M, Tehranchi A, Xu C Q and Kashyap R 2011 Appl. Opt. 50 E108
[10] Richter D, Fried A, Wert B P, Walega J G and Tittel F K 2002 Appl. Phys. B 75 281
[11] Cao Z S, Gao X M, Deng L H, Chen W D, Yuan Y Q, Zhang W J and Gong Z B 2007 Spectrochim Acta Part A: Mol. Biomol. Spectrosc. 68 74
[12] Lancaster D G, Fried A, Wert B, Henry B and Tittel F K 2000 Appl. Opt. 39 4436
[13] Porter J M, Jeffries J B and Hanson R K 2009 Appl. Phys. B 97 215
[14] Wang L, Cao Z, Wang H, Zhao H, Gao W, Yuan Y, Chen W, Zhang W, Wang Y and Gao X 2011 Opt. Commun. 284 358
[15] McCurdy M R, Bakhirkin Y, Wysocki G, Lewicki R and Tittel F K 2007 J. Breath Res. 1 R1
[16] Herriott D, Kogelnik H and Kompfner R 1964 Appl. Opt. 3 523
[17] White J U 1942 J. Opt. Soc. Am. 32 285
[18] Kasyutich V l and Martin P A 2007 Appl. Phys. B 88 125
[19] Takaoka E and Kato K 1999 Appl. Opt. 38 4577
[20] Chen W, Boucher D and Tittel F K 2002 Appl. Phys. 5 27
[21] Cao Z, Han L, Liang W, Deng L, Wang H, Xu C, Chen W, Zhang W, Gong Z and Gao X 2008 Opt. Commun. 281 3878
[22] Sutherland R L, McLean D G and Kirkpatrik S 2003 Handbook of Nonlinear Optics 2nd edn. (New York: Marcel Dekker Inc.) Chap. 2
[23] Chemla D S, Kupecek P J, Robertson D S and Smith R C 1971 Opt. Commun. 3 29
[24] Willer U, Blanke T and Schade W 2001 Appl. Opt. 40 5439
[25] Roberts D A 1996 Appl. Opt. 35 4677
[26] Harasaki A and Kato K 1997 Jpn. J. Appl. Phys. 36 700
[27] Kato K and Shirahata H 1996 Jpn. J. Appl. Phys. 35 4645
[28] Rothman L S et al. 2009 JQSRT 110 533
[29] Klepeis N E, Ott W R and Repace J L 1999 J. Exposure Analysis and Environmental Epidemiology 9 622
[30] Branton P J, McAdam K G, Winter D B, Liu C, Duke M G and Proctor C J 2011 Chemistry Central Journal 5 1
[1] Application of $\alpha$-$\beta$-$\gamma$ filtering to real-time atmosphere methane concentration measurement
Kan Rui-Feng (阚瑞峰), Liu Wen-Qing (刘文清), Zhang Yu-Jun (张玉钧), Liu Jian-Guo (刘建国), Chen Dong (陈东), Wang Min (王敏). Chin. Phys. B, 2006, 15(6): 1379-1383.
[2] Influence of laser intensity in second-harmonic detection with tunable diode laser multi-pass absorption spectroscopy
Kan Rui-Feng (阚瑞峰), Dong Feng-Zhong (董凤忠), Zhang Yu-Jun (张玉钧), Liu Jian-Guo (刘建国), Liu Cheng (刘诚), Wang Min (王敏), Gao Shan-Hu (高山虎), Chen Jun (陈军). Chin. Phys. B, 2005, 14(9): 1904-1909.
No Suggested Reading articles found!