Chin. Phys. B, 2018, Vol. 27(10): 100702    DOI: 10.1088/1674-1056/27/10/100702
GENERAL Prev   Next  

A rapid and convenient experimental method of absolutely calibrating transmission of x-ray flat-response filter

Jian Yu(余建)1, Li-Fei Hou(候立飞)2, Jing Wang(王静)2, Wen-Hai Zhang(张文海)2, Ming Chen(陈铭)2, Bao-Chong Zhou(周保充)2, Sha-Li Xiao(肖沙里)3, Shen-Ye Liu(刘慎业)2
1 Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China;
2 Research Center of Laser Fusion, China Academy of Engineering Physics, P. O. Box 919-986, Mianyang 621900, China;
3 College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
Abstract  

We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flat-response filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction, where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight. We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source, as well as simulation results. Our method is not only highly reliable but also rapid and convenient.

Keywords:  flat-response filter      absolute transmission      flat-field grating spectrometer      x-ray CCD camera  
Received:  15 March 2018      Revised:  06 June 2018      Accepted manuscript online: 
PACS:  07.85.Fv (X- and γ-ray sources, mirrors, gratings, and detectors)  
  41.50.+h (X-ray beams and x-ray optics)  
  42.40.Eq (Holographic optical elements; holographic gratings)  
  42.62.Fi (Laser spectroscopy)  
Fund: 

Project supported by the National Natural Science Foundation of China (Grant Nos. 11405158 and 11775203) and the Presidential Foundation of China Academy of Engineering Physics (Grant No. YZJJLX 2016007).

Corresponding Authors:  Wen-Hai Zhang     E-mail:  xiaoyuercqu@sina.cn

Cite this article: 

Jian Yu(余建), Li-Fei Hou(候立飞), Jing Wang(王静), Wen-Hai Zhang(张文海), Ming Chen(陈铭), Bao-Chong Zhou(周保充), Sha-Li Xiao(肖沙里), Shen-Ye Liu(刘慎业) A rapid and convenient experimental method of absolutely calibrating transmission of x-ray flat-response filter 2018 Chin. Phys. B 27 100702

[1] Lindl J, Amendt P, Berger R, Glendinning S, Glenzer S, Haan S, Kauffman R, Landen O and Amendt P 2004 Phys. Plasmas 11 339
[2] Shang W L, Betti R, Hu S X, Woo K, Hao L, Ren C, Christopherson A R, Bose A and Theobald W 2017 Phys. Rev. Lett. 119 195001
[3] Shang W L, Yang J M and Dong Y S 2013 Appl. Phys. Lett. 102 094105
[4] Theobald W, Bose A, Yan R, Betti R, Lafon M, Mangino D, Christopherson A R, Stoeckl C, Seka W, Shang W, Michel D T, Ren C, Nora R C, Casner A, Peebles J, Beg F N, Ribeyre X, Llor A E, Colaïtis A, Tikhonchuk V and Wei M S 2017 Phys. Plasmas 24 120702
[5] Campbell K M, Weber F A, Dewald E L, Glenzer S H, Landen O L, Turner R E and Waide P A 2004 Rev. Sci. Instrum. 75 3768
[6] Saemann A and Eidmann K 1998 Rev. Sci. Instrum. 69 1949
[7] Hubert S, Dubois J L, Gontier D, Lidove G, Reverdin C, Soullie G, Stemmler P and Villette B 2010 Rev. Sci. Instrum. 81 053501
[8] Bourgade J L, Villette B, Bocher J L, Boutin J Y, Chiche S, Dague N, Gontier D, Jadaud J P, Savale B and Worbel R 2001 Rev. Sci. Instrum. 72 1173
[9] Brown G V, Beiersdorfer P, Emig J, Frankel M, Gu M F, Heeter R F, Magee E, Thorn D B, Widmann K, Kelley R L, Kilbourne C A and Porter F S 2008 Rev. Sci. Instrum. 79 10E309
[10] Li Z, Jiang X, Liu S, Huang T, Zheng J, Yang J, Li S, Guo L, Zhao X, Du H, Song T, Yi R, Liu Y, Jiang S and Ding Y 2010 Rev. Sci. Instrum. 81 073504
[11] Reverdin C, Paurisse M, Caillaud T, Combis P, Duval A, Gontier D, Husson D, Rubbelynck C and Zuber C 2008 Rev. Sci. Instrum. 79 10E932
[12] Lazarchuk V P, Muntyan A N, Murugov V M, Petrov S I and Senik A V 1976 Rev. Sci. Instrum. 47 255
[13] Audley M D, Arnaud K A, Gendreau K C, Boyce K R, Fleetwood C M, Kelley R L, Keski-kuha R A, Scott F, Stahle C K, Szymkowiak A E, Tveekrem J L, Fujimoto R, Mitsuda K, Ishisaki Y and Mihara T 1999 Proc. SPIE 3765 751
[14] Perez F, Kemp G E, Regan S P, Barrios M A, Pino J, Scott H, Ayers S, Chen H, Emig J, Colvin J D, Bedzyk M, Shoup M J, Agliata A, Yaakobi B, Marshall F J, Hamilton R A, Jaquez J, Farrell M, Nikroo A and Fournier K B 2014 Rev. Sci. Instrum. 85 11D613
[15] Kauffman R L, Stradling G, Attwood D T and Medecki H 1983 IEEE J. Quantum Electron. 19 616
[16] Labate L, Galimberti M, Giulietti A, Giulietti D, Gizzi L A, Tomassini P and Cocco G D 2002 Nucl. Instrum. Method A 495 148
[17] Saemann A and Eidmann K 1998 Rev. Sci. Instrum. 69 1949
[18] Stradling G L, Attwood D T and Kauffman R L 1983 IEEE J. Quantum Electron. 19 604
[19] Nakai M, Kondou K, Urasaki T, Sakurai K, Nishimura H, Izawa Y and Yamanaka C 1986 30th Annual Technical Symposium. International Society for Optics and Photonics, August 12, 1986, San Diego, USA, p. 144
[20] Xiong G, Zhang J, Yang G, Yang J, Li H, Hu Z, Zhao Y, Wei M and Yi T 2014 Phys. Scr. 89 065005
[21] Kramida A, Ralchenko Y, Reader J and Team D 2013 NIST At. Spectra Database Version 5.1 (Gaithersburg, MD:National Institute of Standards and Technology) http://physics.nist.gov/asd
[1] Ray tracing method for the grazing incidence flat-field imaging soft X-ray spectrometer
Dong Quan-Li (董全力), Liu Yun-Quan (刘运全), Teng Hao (腾浩), Li Ying-Jun (李英骏), Zhang Jie (张杰). Chin. Phys. B, 2014, 23(6): 065206.
No Suggested Reading articles found!