| ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS |
Prev
Next
|
|
|
Three-dimensional frequency-wavenumber method for efficient and high-quality volumetric ultrasound imaging |
| Huchang Guan(关虎昌)1, Chen Jiang(江晨)2,†, Kailiang Xu(许凯亮)1,3,‡, and Dean Ta(他得安)1,3 |
1 College of Biomedical Engineering, Fudan University, Shanghai 200438, China; 2 Yiwu Research Institute of Fudan University, Yiwu 322000, China; 3 State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai 201203, China |
|
|
|
|
Abstract Total focusing method (TFM) using full matrix capture (FMC) data provides high-quality ultrasound imaging by enabling pixel-level dynamic focusing during both transmission and reception. However, when applied to three-dimensional (3D) ultrasound imaging with a two-dimensional (2D) matrix array (MA), TFM suffers from computational inefficiency due to the conventional delay-and-sum (DAS) algorithm, which limits its applicability in high-volume imaging scenarios. To address this challenge, we introduce an efficient beamforming framework, designated MA-FMC-fk, leveraging the frequency-wavenumber ($f$-$k$) domain to accelerate 3D FMC imaging. The proposed method achieves a computational complexity of $O(N_u^2 N_v^2 N_z \log_2(N_u^2 N_v^2 N_z))$, compared to $O(N_u^2 N_v^2 N_z N_x N_y)$ for the conventional DAS algorithm. The imaging performance of the proposed method was evaluated using simulations, phantom experiments, and in-vivo studies. Quantitative results demonstrate that MA-FMC-fk improves the average lateral resolution by 25.00% for the simulated point targets and by 19.18% for the phantom wire experiments compared to the DAS algorithm. In addition, MA-FMC-fk enhances the average contrast-to-noise ratio (CNR) by 11.73% and the speckle signal-to-noise ratio (sSNR) by 11.16% for the phantom cyst. The MA-FMC-fk algorithm achieves a several-fold reduction in computation time on a CPU-based MATLAB platform relative to DAS. The human experimental results further demonstrate the effectiveness of the proposed method, in which the sSNR and CNR are improved by 19.74% and 18.18%, respectively. The results demonstrate that the MA-FMC-fk method improves image quality while reducing computational cost for 3D TFM imaging using a 2D matrix array.
|
Received: 13 December 2025
Revised: 05 February 2026
Accepted manuscript online: 06 February 2026
|
|
PACS:
|
43.80.Vj
|
(Acoustical medical instrumentation and measurement techniques)
|
| |
43.60.Tj
|
(Wave front reconstruction, acoustic time-reversal, and phase conjugation)
|
| |
87.57.nf
|
(Reconstruction)
|
|
| Fund: Project supported by the National Natural Science Foundation of China (Grant No. 12574495), the National Key Research and Development Program of China (Grant No. 2023YFC2410900), and the Natural Science Foundation of Gansu Province (Grant No. 25JRRG038). |
Corresponding Authors:
Chen Jiang, Kailiang Xu
E-mail: Cjiang17@fudan.edu.cn;xukl@fudan.edu.cn
|
Cite this article:
Huchang Guan(关虎昌), Chen Jiang(江晨), Kailiang Xu(许凯亮), and Dean Ta(他得安) Three-dimensional frequency-wavenumber method for efficient and high-quality volumetric ultrasound imaging 2026 Chin. Phys. B 35 074301
|
[1] Huang Q and Zeng Z 2017 BioMed Res. Int. 2017 6027029 [2] Fenster A and Downey D B 2002 IEEE Eng. Med. Biol. Mag. 15 41 [3] Chang C C, Chen P Y, Huang H and Huang C C 2018 IEEE Trans. Biomed. Eng. 66 1742 [4] Chung S W, Shih C C and Huang C C 2017 Ultrasonics 74 11 [5] Fenster A and Downey D B 2000 Annu. Rev. Biomed. Eng. 2 457 [6] Correia M, Provost J, Tanter M and Pernot M 2016 Phys. Med. Biol. 61 L48 [7] Ramalli A, Boni E, Roux E, Liebgott H and Tortoli P 2022 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 69 2739 [8] Masoumi M H, Kaddoura T and Zemp R J 2023 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 70 460 [9] Fu Y P, Sun Q D, Li B Y, Ta D A and Xu K L 2023 Acta Phys. Sin. 72 074302 (in Chinese) [10] Sun Q, Fu Y, Yan S and Xu K 2025 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 72 202 [11] Sun Q, Hou S, He R, Fu Y, Wu J, Dai J and Xu K 2025 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 72 698 [12] Gonçalves L F, Espinoza J, Kusanovic J P, LeeW, Nien J K, Santolaya- Forgas J, Mari G, Treadwell M C and Romero R 2006 J. Ultrasound Med. 25 745 [13] Provost J, Papadacci C, Arango J E, Imbault M, Fink M, Gennisson J L, Tanter M and Pernot M 2014 Phys. Med. Biol. 59 L1 [14] Gennisson J L, Provost J, Deffieux T, Papadacci C, Imbault M, Pernot Mand Tanter M 2015 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 62 1059 [15] Rabut C, Correia M, Finel V, Pezet S, Pernot M, Deffieux T and Tanter M 2019 Nat. Methods 16 994 [16] Heiles B, Correia M, Hingot V, Pernot M, Provost J, TanterMand Couture O 2019 IEEE Trans. Med. Imaging 38 2005 [17] Bureau F, Robin J, Le Ber A, Lambert W, Fink M and Aubry A 2023 Nat. Commun. 14 6793 [18] Yan J, Wang B, Riemer K, Hansen-Shearer J, Lerendegui M, Toulemonde M, Rowlands C J, Weinberg P D and Tang M X 2023 IEEE Trans. Biomed. Eng. 70 2752 [19] Zhang C, Lei S, Ma A, Wang B, Wang S, Liu J, Shang D, Zhang Q, Li Y, Zheng H and Ma T 2024 Eur. Radiol. 34 5250 [20] Wu X and Lee W N 2024 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 71 659 [21] Wu X and Lee W N 2025 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 72 817 [22] Sun L J, Han Q B and Jin Q L 2025 Chin. Phys. B 34 014301 [23] Stolt R H 1978 Geophysics 43 23 [24] Cafforio C, Prati C and Rocca F 2002 IEEE Trans. Aerosp. Electron. Syst. 27 194 [25] Soumekh M 2002 IEEE Signal Process. Mag. 12 21 [26] Lu J Y 1997 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 44 839 [27] Garcia D, Le Tarnec L, Muth S, Montagnon E, Porée J and Cloutier G 2013 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 60 1853 [28] Bernard O, Zhang M, Varray F, Gueth P, Thiran J P, Liebgott H and Friboulet D 2014 Proc. IEEE Int. Ultrason. Symp. (Chicago) p. 129 [29] AlbulayliMand Rakhmatov D 2018 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 65 1321 [30] Zhang M, Varray F, Besson A, Carrillo R E, Viallon M, Garcia D, Thiran J P, Friboulet D, Liebgott H and Bernard O 2016 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 63 2125 [31] Stepinski T 2007 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 54 1399 [32] Hunter A J, Drinkwater B W and Wilcox P D 2008 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 55 2450 [33] Vos H J, van Neer P L, Mota M M, Verweij M D, van der Steen A F and Volker A W 2015 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 63 60 [34] Moghimirad E, Hoyos C A V, Mahloojifar A, Asl B M and Jensen J A 2016 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 63 2018 [35] Guo H, Freear S and Zhou G Q 2024 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 71 972 [36] Cheng J and Lu J Y 2006 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 53 880 [37] Merabet L, Robert S and Prada C 2019 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 66 772 [38] Marmonier M, Robert S, Laurent J and Prada C 2022 Ultrasonics 124 106708 [39] Lin S C and Li P C 2023 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 71 85 [40] Li M, Liang S and Lu M 2024 Phys. Med. Biol. 69 185008 [41] Liu J, Jiang C, Liu C, Xu K and Ta D Chin. Phys. B (Submitted) [42] Guan H, Jiang C, Xu K and Ta D 2025 Ultrasonics 158 107809 [43] Wang P, Ma H, Liu T, Liu C, Li D and Ta D 2025 Chin. Phys. B 34 044301 [44] Rodriguez-Molares A, Rindal O M H, D’hooge J, Måsøy S E, Austeng A, Bell M A L and Torp H 2019 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 67 745 [45] Zhao J J, Jin S M,Wang Y K,Wang Y and Peng Y H 2025 Chin. Phys. B 34 084301 |
| No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.