Acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction |
Li Yi-Ling(李宜令)a), Ma Qing-Yu(马青玉) b)†, Zhang Dong(章东)c), and Xia Rong-Min(夏荣民)d) |
a Department of Educational Technology, Nanjing Normal University, Nanjing 210097, China; b Key Laboratory of Optoelectronics of Jiangsu Province, School of Physics and Technology, Nanjing Normal University, Nanjing 210046, China; c Institute of Acoustics, Nanjing University, Nanjing 210093, China; d University of Arkansas for Medical Science, Little Rock, AR 72205, USA |
|
|
Abstract An acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction (MAT-MI) is proposed, based on the analyses of one-dimensional tissue vibration, three-dimensional acoustic dipole radiation and acoustic waveform detection with a planar piston transducer. The collected waveforms provide information about the conductivity boundaries in various vibration intensities and phases due to the acoustic dipole radiation pattern. Combined with the simplified back projection algorithm, the conductivity configuration of the measured layer in terms of shape and size can be reconstructed with obvious border stripes. The numerical simulation is performed for a two-layer cylindrical phantom model and it is also verified by the experimental results of MAT-MI for a tissue-like sample phantom. The proposed model suggests a potential application of conductivity differentiation and provides a universal basis for the further study of conductivity reconstruction for MAT-MI.
|
Received: 22 January 2011
Revised: 18 March 2011
Accepted manuscript online:
|
PACS:
|
43.80.Ev
|
(Acoustical measurement methods in biological systems and media)
|
|
72.55.+s
|
(Magnetoacoustic effects)
|
|
73.50.Rb
|
(Acoustoelectric and magnetoacoustic effects)
|
|
Fund: Project supported by the National Basic Research Program of China (Grant No. 2011CB707900), the National Natural Science
Foundation of China (Grant No. 10974098), the Natural Science Foundation of Jiangsu Province, China (Grant No. BK2009407),
and the Specialized Research Fund for Doctoral Program of High Education of China (Grant No. 20093207120003). |
Cite this article:
Li Yi-Ling(李宜令), Ma Qing-Yu(马青玉), Zhang Dong(章东), and Xia Rong-Min(夏荣民) Acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction 2011 Chin. Phys. B 20 084302
|
[1] |
Paulson K, Lionheart W and Pidecock M 1993 IEEE Trans. Med. Imag. 12 681
|
[2] |
Zedehkoochak M, Blott B H, Hamse T K and George R F 1991 J. Phys. D: Appl. Phys. 24 1911.
|
[3] |
Metheral P, Barber D C, Smallwood R H and Brown B H 1996 Nature 380 509
|
[4] |
Al-Zeibak S, Goss D, Lyon G, Yu Z Z, Peyton A J and Beck M S 1995 Proc. 9th Int. Conf. on Electrical Bio-Impedance Heidelberg, Germany p. 426
|
[5] |
Griffiths H 2001 Meas. Sci. Technol. 12 1126
|
[6] |
Kwon O, Woo E J, Yoon J R and Seo J K 2002 IEEE Trans. Biomed. Eng. 49 160
|
[7] |
Ider Y Z and Onart S 2004 Phys. Meas. 25 281
|
[8] |
Gao N and He B 2008 IEEE Trans. Biomed. Eng. 55 1530
|
[9] |
Wen H 1999 Ultrason. Imag. 21 186
|
[10] |
Roth B J, Basser P J and Wikswo J P 1994 IEEE Trans. Biomed. Eng. 41 723
|
[11] |
Xu Y and He B 2005 Phys. Med. Biol. 50 5175
|
[12] |
Li X, Xu Y and He B 2006 J. Appl. Phys. 99 066112
|
[13] |
Li X, Xu Y and He B 2007 IEEE Trans. Biomed. Eng. 54 323
|
[14] |
Xia R, Li X and He B 2007 Appl. Phys. Lett. 91 083903
|
[15] |
Brinker K and Roth B J 2008 IEEE Trans. Biomed. Eng. 55 1637
|
[16] |
Li Y L, Liu Z B, Ma Q Y and Guo X S 2010 Chin. Phys. Lett. 27 084302
|
[17] |
Ma Q Y and He B 2007 Phys. Med. Biol. 52 5085
|
[18] |
Ma Q Y and He B 2008 IEEE Trans. Biomed Eng. 55 813
|
[19] |
Li X, Li X, Zhu S N and He B 2009 Phys. Med. Biol. 54 2667
|
[20] |
Kinsler L E, Frey A R, Coppens A B and Sanders J V 2000 Fundamentals of Acoustics 4th edn. (New York: John Wiley & Sons)
|
[21] |
Morse P M and Feshbach H 1953 Methods of Theoretical Physics (New York: McGraw-Hill)
|
[22] |
Du G H, Zhu Z M and Gong X F 2001 Fundamentals of Acoustics (Nanjing: Nanjing University Press)
|
[23] |
Zhang H Y, Cao Y P, Sun X L, Chen X H and Yu J B 2010 Chin. Phys. B 19 114301
|
[24] |
Wang L Y, Li L, Yan B, Jiang C S, Wang H Y and Bao S L 2010 Chin. Phys. B 19 088106
|
[25] |
Xu Y and Wang L H 2004 Phys. Rev. Lett. 92 033902
|
[26] |
Li W, Liu S B and Yang W 2010 Chin. Phys. B 19 030307
|
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.
View more on Altmetrics
|
|
|