Please wait a minute...
Chin. Phys. B, 2013, Vol. 22(4): 044103    DOI: 10.1088/1674-1056/22/4/044103
ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS Prev   Next  

Polycapillary X-ray lens for secondary focusing Beijing synchrotron radiation source

Li Yu-Dea, Lin Xiao-Yana, Liu Shi-Ganga, He Jin-Longa, Guo Feia, Sun Tian-Xia, Liu Pengb
a The Key Laboratory of Beam Technology and Material Modification of Ministry of Education, College of Nuclear Science and Technology ofBeijing Normal University, Beijing Radiation Center, Beijing 100875, China;
b Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
Abstract  According to the intensity distribution of synchrotron radiation source focused by toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, the theoretical modeling of Beijing synchrotron radiation source is developed for capillary optics. With this theoretical modeling, the influences of configuration curve of polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of transmission efficiency and working distance at the biological macromolecule station are in good agreement with theoretical results.
Keywords:  Beijing synchrotron radiation facility      polycapillary X-ray lens      secondary focusing     
Received:  01 February 2013      Published:  01 March 2013
PACS:  41.50.+h (X-ray beams and x-ray optics)  
  07.85.-m (X- and γ-ray instruments)  
Fund: Project supported by the National Natural Science Foundation of China (Grant Nos. 11179010 and 11075017 ), the Natural Science Foundation of Beijing, China (Grant No. 1102019), and the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20100003120010).
Corresponding Authors:  Li Yu-De     E-mail:  Liyude@bnu.edu.cn

Cite this article: 

Li Yu-De, Lin Xiao-Yan, Liu Shi-Gang, He Jin-Long, Guo Fei, Sun Tian-Xi, Liu Peng Polycapillary X-ray lens for secondary focusing Beijing synchrotron radiation source 2013 Chin. Phys. B 22 044103

[1] So I, Siddons D P, Caliebe W A and Khalid S 2007 Nucl. Instrum. Methods Phys. Res. Sec. A 582 190
[2] Noyan I C, Wang P C, Kaldor S K, Jordan-Sweet J L and Liniger E G 2000 Rev. Sci. Instrum. 71 1991
[3] Wei S Q, Sun Z H, Pan Z Y, Zhang X Y, Yan W S and Zhong W 2006 Nucl. Sci. Tech. 17 370
[4] Xu X D, Hong Y L, Fu S D and Zhang Y W 1999 Physics 28 236 (in Chinese)
[5] Wu P J, Li Y D, Lin X Y, Liu A D and Sun T X 2005 Acta Phys. Sin. 54 4478 (in Chinese)
[6] Lin X Y, Li Y D, Tan G T and Sun T X 2007 Nucl. Instrum. Methods Phys. Res. Sec. A 572 729
[7] Ullich J B, Kovantsev V and MacDonald C A 1993 J. Appl. Phys. 74 5933
[8] Wang L, Rath B K, Gibson W M, Kimball J C and McDonalds C A 1996 J. Appl. Phys. 80 3628
[9] Furuta K, Nakayama Y, Shoji M, Kaigawa R, Hanamoto K, Nakano H and Hosokawa Y 1993 Rev. Sci. Instrum. 64 135
[10] Vincze L, Janssens K, Adams F, Rindby A and Engstrom P 1998 Rev. Sci. Instrum. 69 3494
[11] Chen B Z 2000 Nucl. Instrum. & Methods Phys. Res. B 170 230
[12] Liu A D 2004 Math. Comput. Simul. 65 251
[13] Liu A D and Lin Y 2004 Math. Comput. Simul. 66 577
[14] Liu A D 2005 Nucl. Instrum. & Methods Phys. Res. B 234 555
[1] Focusing high-energy x-rays by a PMMA compound x-ray lens on Beijing synchrotron radiation facility
Le Zi-Chun, Dong Wen, Zhu Pei-Ping, Peng Liang-Qiang, Huang Wan-Xia, Yuan Qing-Xi, Wang Jun-Yue, Liang Jing-Qiu, Wang Wei-Biao. Chin. Phys. B, 2007, 16(4): 984-988.
No Suggested Reading articles found!