ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS |
Prev
Next
|
|
|
Non-invasive and low-artifact in vivo brain imaging by using a scanning acoustic-photoacoustic dual mode microscopy |
Wentian Chen(陈文天)1, Chao Tao(陶超)1,†, Zizhong Hu(胡仔仲)2, Songtao Yuan(袁松涛)2,‡, Qinghuai Liu(刘庆淮)2, and Xiaojun Liu(刘晓峻)1,§ |
1 Ministry-of-Education Key Laboratory of Modern Acoustics, Department of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093, China; 2 Department of Ophthalmology, The First Affiliated Hospital of Nanjing Medial University, Nanjing 210029, China |
|
|
Abstract Photoacoustic imaging is a potential candidate for in vivo brain imaging, whereas, its imaging performance could be degraded by inhomogeneous multi-layered media, consisted of scalp and skull. In this work, we propose a low-artifact photoacoustic microscopy (LAPAM) scheme, which combines conventional acoustic-resolution photoacoustic microscopy with scanning acoustic microscopy to suppress the reflection artifacts induced by multi-layers. Based on similar propagation characteristics of photoacoustic signals and ultrasonic echoes, the ultrasonic echoes can be employed as the filters to suppress the reflection artifacts to obtain low-artifact photoacoustic images. Phantom experiment is used to validate the effectiveness of this method. Furthermore, LAPAM is applied for in-vivo imaging mouse brain without removing the scalp and the skull. Experimental results show that the proposed method successfully achieves the low-artifact brain image, which demonstrates the practical applicability of LAPAM. This work might improve the photoacoustic imaging quality in many biomedical applications which involve tissues with complex acoustic properties, such as brain imaging through scalp and skull.
|
Received: 20 August 2021
Revised: 25 November 2021
Accepted manuscript online: 12 January 2022
|
PACS:
|
43.35.Ud
|
(Thermoacoustics, high temperature acoustics, photoacoustic effect)
|
|
43.35.Sx
|
(Acoustooptical effects, optoacoustics, acoustical visualization, Acoustical microscopy, and acoustical holography)
|
|
78.20.Pa
|
(Photoacoustic effects)
|
|
81.70.Cv
|
(Nondestructive testing: ultrasonic testing, photoacoustic testing)
|
|
Fund: Project supported by the National Natural Science Foundation of China (Grant Nos. 12027808, 11874217, 11834008, 81900875, and 81770973) and Natural Science Foundation of Jiangsu Province, China (Grant No. BK 20181077). |
Corresponding Authors:
Chao Tao, Songtao Yuan, Xiaojun Liu
E-mail: taochao@nju.edu.cn;yuansongtao@vip.sina.com;liuxiaojun@nju.edu.cn
|
Cite this article:
Wentian Chen(陈文天), Chao Tao(陶超), Zizhong Hu(胡仔仲), Songtao Yuan(袁松涛), Qinghuai Liu(刘庆淮), and Xiaojun Liu(刘晓峻) Non-invasive and low-artifact in vivo brain imaging by using a scanning acoustic-photoacoustic dual mode microscopy 2022 Chin. Phys. B 31 044304
|
[1] Wang L V and Hu S 2012 Science 335 1458 [2] Seong M and Chen S L 2020 Sci. China Life Sci. 63 1798 [3] Ntziachristos V 2010 Nat. Methods 7 603 [4] Zhang W, Li Y, Nguyen V P, Derouin K, Xia X, Paulus Y M and Wang X 2020 J. Biomed. Opt. 25 066003 [5] Jin T, Guo H, Jiang H, Ke B and Xi L 2017 Opt. Lett. 42 4434 [6] Yao J, Xia J and Wang L V 2016 Ultrason Imaging 38 44 [7] Nguyen V P, Li Y, Qian W, Liu B, Tian C, Zhang W, Huang Z, Ponduri A, Tarnowski M, Wang X and Paulus Y M 2019 Sci. Rep. 9 5945 [8] Tian C, Zhang W, Mordovanakis A, Wang X and Paulus Y M 2017 Opt. Express 25 15947 [9] Moothanchery M, Seeni R Z, Xu C and Pramanik M 2017 Biomed. Opt. Express 8 5483 [10] Tian C, Zhang W, Nguyen V P, Wang X and Paulus Y M 2018 J. Vis. Exp. 132 e57135 [11] Zhang H F, Maslov K, Stoica G and Wang L V 2006 Nature Biotechnol. 24 848 [12] Leng X, Chapman W, Rao B, Nandy S, Chen R, Rais R, Gonzalez I, Zhou Q, Chatterjee D, Mutch M and Zhu Q 2018 Biomed. Opt. Express 9 5159 [13] Yang X, Zhang Y, Zhao K, Zhao Y, Liu Y, Gong H, Luo Q and Zhu D 2016 IEEE Trans. Med. Imaging 35 1903 [14] Yao J and Wang L V 2014 Neurophoton 1 011003 [15] Stein E W, Maslov K and Wang L V 2009 J. Appl. Phys. 105 102027 [16] Stein E W, Maslov K and Wang L V 2009 J. Biomed. Opt. 14 020502 [17] Kneipp M, Turner J, Estrada H, Rebling J, Shoham S and Razansky D 2016 J. Biophotonics 9 117 [18] Brunker J and Beard P 2016 Sci. Rep. 6 20902 [19] Wang L, Xia J, Yao J, Maslov K and Wang L V 2013 Phys. Rev. Lett. 111 204301 [20] Jeon S, Park J, Managuli R and Kim C 2019 IEEE Trans. Med. Imaging 38 250 [21] Mohammadi L, Behnam H, Tavakkoli J and Avanaki K 2020 Biomed. Opt. Express 11 5542 [22] Baik J W, Kim J Y, Cho S, Choi S, Kim J and Kim C 2020 IEEE Trans. Med. Imaging 39 975 [23] Yang Y and Yang S H 2012 Chin. Phys. B 21 054211 [24] Wang S, Tao C and Liu X 2013 Chin. Phys. B 22 074303 [25] Chen W, Tao C, Nguyen N Q, Prager R W and Liu X 2020 Opt. Lett. 45 3840 [26] Gao X, Tao C, Wang X and Liu X 2015 Opt. Lett. 40 970 [27] Liu Z, Tao C and Liu X 2019 Appl. Phys. Express 12 057001 [28] Dai N, Tao C, Gao X, Chen W, Zhang X and Liu X 2020 Appl. Phys. Express 13 017005 [29] Lv X, Xu X, Feng Q, Zhang B, Ding Y and Liu Q 2020 Chin. Phys. B 29 034301 [30] Mozaffarzadeh M, Varnosfaderani M H H, Sharma A, Pramanik M, Jong N and Verweij M D 2019 J. Biophotonics 12 e201900133 [31] Guo Z, Li Y and Chen S L 2018 Opt. Lett. 43 1119 [32] Moothanchery M and Pramanik M 2017 Sensors 17 357 [33] Singh M K A, Jaeger M, Frenz M and Steenbergen W 2016 Biomed. Opt. Express 7 2955 [34] Singh M K A and Steenbergen W 2015 Photoacoustics 3 123 [35] Allman D, Reiter A and Bell M A L 2018 IEEE Trans. Med. Imaging 37 1464 [36] Nguyen H N Y, Hussain A and Steenbergen W 2018 Biomed. Opt. Express 9 4613 [37] Chen W, Tao C and Liu X 2019 Opt. Lett. 44 1273 [38] Zhang X, Qian X, Tao C and Liu X 2018 Ultrasound Med. Biol. 44 1110 [39] Maev R G 2013 Advances in Acoustic Microscopy and High Resolution Imaging from Principles to Applications (Weinheim:Wiley-VCH Verlag & Co. KGaA) p. 98 [40] Rahman M F A, Arshad M R, Manaf A A and Yaacob M I H 2012 Indian J. Mar. Sci. 41 557 [41] Liang B, Liu W, Zhan Q, Li M, Zhuang M, Liu Q H and Yao J 2019 J. Biophotonics 12 e201800466 [42] Kobayashi K, Yoshida S, Saijo Y and Hozumi N 2014 Ultrasonics 54 1922 |
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
Altmetric
|
blogs
Facebook pages
Wikipedia page
Google+ users
|
Online attention
Altmetric calculates a score based on the online attention an article receives. Each coloured thread in the circle represents a different type of online attention. The number in the centre is the Altmetric score. Social media and mainstream news media are the main sources that calculate the score. Reference managers such as Mendeley are also tracked but do not contribute to the score. Older articles often score higher because they have had more time to get noticed. To account for this, Altmetric has included the context data for other articles of a similar age.
View more on Altmetrics
|
|
|