中国物理B ›› 2011, Vol. 20 ›› Issue (3): 30509-030509.doi: 10.1088/1674-1056/20/3/030509
罗小光, 何济洲
Luo Xiao-Guang(罗小光) and He Ji-Zhou(何济洲)†
摘要: Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and the coefficient of performance are plotted by numerical calculation. It is shown that the maximum cooling rate of the thermoelectric refrigerator with two resonances increases but the maximum coefficient of performance decreases compared with those with one resonance. No matter which resonance mechanism is used (kx or kr filtered), the cooling rate and the performance coefficient of the kr filtered refrigerator are much better than those of the kx filtered one.
中图分类号: (Nonequilibrium and irreversible thermodynamics)