中国物理B ›› 2009, Vol. 18 ›› Issue (1): 203-208.doi: 10.1088/1674-1056/18/1/033

• • 上一篇    下一篇

2D parameter optimization of Ne-like Cr x-ray laser on slab

李英骏1, 袁素英1, 程涛2, 孟立民2, 张杰3   

  1. (1)China University of Mining and Technology, Beijing 100083, China; (2)China University of Mining and Technology, Beijing 100083, China;Laboratory of Optical Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China; (3)Laboratory of Optical Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
  • 收稿日期:2008-05-03 修回日期:2008-08-19 出版日期:2009-01-20 发布日期:2009-01-20
  • 基金资助:
    Project supported by the National Natural Science Foundation of China (Grant Nos 10474137, 10874242 and 10775018), the National Basic Research Program of China (Grant No 2007CB815105), and the Specialized Research Fund for the Doctoral Program of Higher E

2D parameter optimization of Ne-like Cr x-ray laser on slab

Cheng Tao(程涛)a)b), Li Ying-Jun(李英骏)a), Meng Li-Min(孟立民)a)b), Yuan Su-Ying(袁素英)a), and Zhang Jie(张杰)b)   

  1. a China University of Mining and Technology, Beijing 100083, China; b Laboratory of Optical Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
  • Received:2008-05-03 Revised:2008-08-19 Online:2009-01-20 Published:2009-01-20
  • Supported by:
    Project supported by the National Natural Science Foundation of China (Grant Nos 10474137, 10874242 and 10775018), the National Basic Research Program of China (Grant No 2007CB815105), and the Specialized Research Fund for the Doctoral Program of Higher E

摘要: A method of studying a non-equilibrium x-ray laser plasma is developed by extending the existing one-dimensional similarity equations to the case of two-dimensional plasma study in the directions perpendicular to the slab and along a focal line. With this method the characteristics of pre-plasma are optimized for transient neon-like Cr x-ray laser. It is found that when the duration and the intensity of 1.053μm pre-pulse are 1.2ns and 6.5 TW/cm2 respectively with a delay time of 1.5ns, the temperature and the temperature discrepancy each approach a proper state, which will provide a uniform distribution of properly ionized neon-like Cr ions before the arrival of pumping pulse.

关键词: x-ray laser, two-dimensional hydrodynamic evolution, laser plasma

Abstract: A method of studying a non-equilibrium x-ray laser plasma is developed by extending the existing one-dimensional similarity equations to the case of two-dimensional plasma study in the directions perpendicular to the slab and along a focal line. With this method the characteristics of pre-plasma are optimized for transient neon-like Cr x-ray laser. It is found that when the duration and the intensity of 1.053μm pre-pulse are 1.2ns and 6.5 TW/cm2 respectively with a delay time of 1.5ns, the temperature and the temperature discrepancy each approach a proper state, which will provide a uniform distribution of properly ionized neon-like Cr ions before the arrival of pumping pulse.

Key words: x-ray laser, two-dimensional hydrodynamic evolution, laser plasma

中图分类号:  (X- and γ-ray lasers)

  • 42.55.Vc
52.38.Ph (X-ray, γ-ray, and particle generation)