Coherence transfer from 1064 nm to 578 nm using an optically referenced frequency comb

方苏, 蒋燕义, 陈海琴, 姚远, 毕志毅, 马龙生   

  1. State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China
  • 收稿日期:2014-12-16 修回日期:2015-02-01 出版日期:2015-07-05 发布日期:2015-07-05
  • 基金资助:

    Project supported by the National Natural Science Foundation of China (Grant Nos. 11334002, 11374102, 11104077, and 11127405) and the National Basic Research Program of China (Grant No. 2012CB821302).

Coherence transfer from 1064 nm to 578 nm using an optically referenced frequency comb

Fang Su (方苏), Jiang Yan-Yi (蒋燕义), Chen Hai-Qin (陈海琴), Yao Yuan (姚远), Bi Zhi-Yi (毕志毅), Ma Long-Sheng (马龙生)   

  1. State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China
  • Received:2014-12-16 Revised:2015-02-01 Online:2015-07-05 Published:2015-07-05
  • Contact: Jiang Yan-Yi E-mail:yyjiang@phy.ecnu.edu.cn
  • Supported by:

    Project supported by the National Natural Science Foundation of China (Grant Nos. 11334002, 11374102, 11104077, and 11127405) and the National Basic Research Program of China (Grant No. 2012CB821302).

摘要:

A laser at 578 nm is phase-locked to an optical frequency comb (OFC) which is optically referenced to a subhertz-linewidth laser at 1064 nm. Coherence is transferred from 1064 nm to 578 nm via the OFC. By comparing with a cavity-stabilized laser at 578 nm, the absolute linewidth of 1.1 Hz and the fractional frequency instability of 1.3× 10-15 at an averaging time of 1 s for each laser at 578 nm have been determined, which is limited by the performance of the reference laser for the OFC.

关键词: coherence transfer, optical frequency comb, narrow linewidth laser

Abstract:

A laser at 578 nm is phase-locked to an optical frequency comb (OFC) which is optically referenced to a subhertz-linewidth laser at 1064 nm. Coherence is transferred from 1064 nm to 578 nm via the OFC. By comparing with a cavity-stabilized laser at 578 nm, the absolute linewidth of 1.1 Hz and the fractional frequency instability of 1.3× 10-15 at an averaging time of 1 s for each laser at 578 nm have been determined, which is limited by the performance of the reference laser for the OFC.

Key words: coherence transfer, optical frequency comb, narrow linewidth laser