中国物理B ›› 2011, Vol. 20 ›› Issue (4): 47701-047701.doi: 10.1088/1674-1056/20/4/047701
张超1, 江小宁2, 马廷锋3, 冯冠平4
Ma Ting-Feng(马廷锋)a), Zhang Chao(张超)b)† , Jiang Xiao-Ning(江小宁)c), and Feng Guan-Ping(冯冠平)a)b)
摘要: Quartz crystal resonators (QCRs) with circular electrodes have been widely used for various liquid and gas sensing applications. In this work, quartz crystal resonators with elliptical electrodes were studied and tested for liquid property measurement. Mindlin's theory was used to optimize the dimension and geometry of the electrodes and a 5-MHz QCR with minimum series resistance and without any spurious modes was obtained. A series of AT-cut QCRs with elliptical electrodes of different sizes were fabricated and their sensing performances were compared to devices with circular electrodes. The experimental result shows that the device with elliptical electrodes can obtain lower resonance impedance and a higher Q factor, which results in a better loading capability. Even though the sensitivities of devices with elliptical and circular electrodes are found to be similar, the sensor with elliptical electrodes has much higher resolution due to a better frequency stability. The study indicates that the performance of QCRs with elliptical electrodes is superior to that of traditional QCRs with circular electrodes.
中图分类号: (Dielectric, piezoelectric, ferroelectric, and antiferroelectric materials)