中国物理B ›› 2018, Vol. 27 ›› Issue (2): 24101-024101.doi: 10.1088/1674-1056/27/2/024101

• ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS • 上一篇    下一篇

Higher order harmonics suppression in extreme ultraviolet and soft x-ray

Yong Chen(陈勇), Lai Wei(魏来), Feng Qian(钱凤), Zuhua Yang(杨祖华), Shaoyi Wang(王少义), Yinzhong Wu(巫殷忠), Qiangqiang Zhang(张强强), Quanpin Fan(范全平), Leifeng Cao(曹磊峰)   

  1. Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900, China
  • 收稿日期:2017-08-25 修回日期:2017-10-07 出版日期:2018-02-05 发布日期:2018-02-05
  • 通讯作者: Leifeng Cao E-mail:leifeng.cao@caep.cn
  • 基金资助:
    Project supported by the National Key Research and Development Program of China (Grant No. 2017YFA0206004), the National Natural Science Foundation of China (Grant No. 11375160), and the National Science Instruments Major Project of China (Grant No. 2012YQ130125).

Higher order harmonics suppression in extreme ultraviolet and soft x-ray

Yong Chen(陈勇), Lai Wei(魏来), Feng Qian(钱凤), Zuhua Yang(杨祖华), Shaoyi Wang(王少义), Yinzhong Wu(巫殷忠), Qiangqiang Zhang(张强强), Quanpin Fan(范全平), Leifeng Cao(曹磊峰)   

  1. Science and Technology on Plasma Physics Laboratory, Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900, China
  • Received:2017-08-25 Revised:2017-10-07 Online:2018-02-05 Published:2018-02-05
  • Contact: Leifeng Cao E-mail:leifeng.cao@caep.cn
  • About author:41.85.Si; 42.25.Fx; 07.85.Nc; 42.79.Dj
  • Supported by:
    Project supported by the National Key Research and Development Program of China (Grant No. 2017YFA0206004), the National Natural Science Foundation of China (Grant No. 11375160), and the National Science Instruments Major Project of China (Grant No. 2012YQ130125).

摘要: The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order harmonics suppression with single order diffraction gratings in extreme ultraviolet and soft x-ray. The principle of harmonic suppression with single order diffraction grating is described, and an extreme ultraviolet and soft x-ray non-harmonics grating monochromator is designed based on the single order diffraction grating. The performance is simulated by an optical design software. The emergent beams of a monochromator with different gratings are measured by a transmission grating spectrometer. The results show that the single order diffraction grating can suppress higher order harmonics effectively, and it is expected to be widely used in synchrotron radiation, diagnostics of laser induced plasma, and astrophysics.

关键词: higher order harmonics suppression, extreme ultraviolet and soft x-ray, monochromator, single order diffraction grating

Abstract: The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order harmonics suppression with single order diffraction gratings in extreme ultraviolet and soft x-ray. The principle of harmonic suppression with single order diffraction grating is described, and an extreme ultraviolet and soft x-ray non-harmonics grating monochromator is designed based on the single order diffraction grating. The performance is simulated by an optical design software. The emergent beams of a monochromator with different gratings are measured by a transmission grating spectrometer. The results show that the single order diffraction grating can suppress higher order harmonics effectively, and it is expected to be widely used in synchrotron radiation, diagnostics of laser induced plasma, and astrophysics.

Key words: higher order harmonics suppression, extreme ultraviolet and soft x-ray, monochromator, single order diffraction grating

中图分类号:  (Particle beam collimators, monochromators)

  • 41.85.Si
42.25.Fx (Diffraction and scattering) 07.85.Nc (X-ray and γ-ray spectrometers) 42.79.Dj (Gratings)