Cite this article:
Dong Jia-Fu, Shi Bing-Ren, Li Wei, Luo Jun-Lin, Liu Yi, Fu Bing-Zhong, Dong Yun-Bo, Xiao Zheng-Gui, Zheng Yin-Jia, Qin Yun-Wen. Determination of q=1 surface by the variation of pellet ablation rate on the HL-1MJ. Chin. Phys. B, 2004, 13(3): 379-383.
| Dong Jia-Fu, Shi Bing-Ren, Li Wei, Luo Jun-Lin, Liu Yi, Fu Bing-Zhong, Dong Yun-Bo, Xiao Zheng-Gui, Zheng Yin-Jia, Qin Yun-Wen. Determination of q=1 surface by the variation of pellet ablation rate on the HL-1MJ. Chin. Phys. B, 2004, 13(3): 379-383. |
Determination of q=1 surface by the variation of pellet ablation rate on the HL-1M
-
Abstract
Strong drop of H\alpha emission has been observed on the HL-1M tokamak by means of a detector array while a pellet crosses the q=1 surface. In this article, the q=1 surface has been determined precisely by the interval and the shape of the Hα emission striations on the pellet trajectory due to the variation of pellet ablation rate. The q-profile and current density distribution at the plasma centre region have been calculated according to the pellet ablation rate and the magnetic shear feature. -
DownLoad: