Cite this article:
Chen Xiao, Xiao Qi-Rong, Jin Guang-Yong, Yan Ping, Gong Ma-Li. High coupling efficiency and low signal light loss (2+1)× 1 couplerJ. Chin. Phys. B, 2015, 24(6): 064208.
| Chen Xiao, Xiao Qi-Rong, Jin Guang-Yong, Yan Ping, Gong Ma-Li. High coupling efficiency and low signal light loss (2+1)× 1 couplerJ. Chin. Phys. B, 2015, 24(6): 064208. |
High coupling efficiency and low signal light loss (2+1)× 1 coupler
-
Abstract
The coupling efficiency of the pump coupler determines the pump light injection capacity of a laser system. Experimental analysis of the influences of different factors on the pump coupling efficiency is in accordance with this conclusion. We use two Nufern fibers (400 μm/440 μm with NA = 0.22) as pump arm, one Nufern fiber (20 μm/400 μm with NA = 0.06/0.46) as a main fiber to make a side-pumping (2+1)× 1 coupler. The experimental result shows that the total output power of this (2+1)× 1 coupler is about 1160 W, corresponding to a coupling efficiency as high as 98.6%. The loss of signal light is less than 1%. -
DownLoad: