Print ISSN:1674-1056  |  Online ISSN:2058-3834  |  CN:11-5639/O4
  • Cite this article:

    Yang Ai-Lin, Yang Guo-Qing, Cai Xun-Ming, Xu Yun-Fei, Lin Qiang. A laser pump-re-pump atomic magnetometerJ. Chin. Phys. B, 2013, 22(12): 120702.
    Yang Ai-Lin, Yang Guo-Qing, Cai Xun-Ming, Xu Yun-Fei, Lin Qiang. A laser pump-re-pump atomic magnetometerJ. Chin. Phys. B, 2013, 22(12): 120702.
  • A laser pump-re-pump atomic magnetometer

    • We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the conventional method using one radiation field, which is used not only as the probe beam but also as a pump beam, the additional re-pump beam can increase remarkably the amplitude of the signal. It is shown that the amplitude of the magnetic field resonance signal can increase more than 55% by using an additional re-pump beam, which makes the sensitivity of the magnetometer higher. Finally, we investigate the relation between amplitude of the signal and re-pump laser power, and calculate the atomic population in the trapping states with rate equations.
    • Article Text

    • loading

    Catalog

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return