Print ISSN:1674-1056  |  Online ISSN:2058-3834  |  CN:11-5639/O4
  • Cite this article:

    Li Mo, Wu Jian, Wang Liang-Ping, Wu Gang, Han Juan-Juan, Guo Ning, Qiu Meng-Tong. Electron temperature diagnostics of aluminium plasma in z-pinch experiment on “QiangGuang-1” facilityJ. Chin. Phys. B, 2012, 21(12): 125202.
    Li Mo, Wu Jian, Wang Liang-Ping, Wu Gang, Han Juan-Juan, Guo Ning, Qiu Meng-Tong. Electron temperature diagnostics of aluminium plasma in z-pinch experiment on “QiangGuang-1” facilityJ. Chin. Phys. B, 2012, 21(12): 125202.
  • Electron temperature diagnostics of aluminium plasma in z-pinch experiment on “QiangGuang-1” facility

    • Two curved crystal spectrometers are setup on "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. The Kodak Biomax-MS film and IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV~520 eV)± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on ~1 MA facility.
    • Article Text

    • loading

    Catalog

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return