Print ISSN:1674-1056  |  Online ISSN:2058-3834  |  CN:11-5639/O4
  • Cite this article:

    Han He-Tong, Wang Qun-Shu, Xia Liang-Bin, Guan Xing-Yin, Zhang Zi-Chuan. Design and gamma sensitivity measurement of a novel dual-emitter vacuum Compton detectorJ. Chin. Phys. B, 2009, 18(11): 4777-4780.
    Han He-Tong, Wang Qun-Shu, Xia Liang-Bin, Guan Xing-Yin, Zhang Zi-Chuan. Design and gamma sensitivity measurement of a novel dual-emitter vacuum Compton detectorJ. Chin. Phys. B, 2009, 18(11): 4777-4780.
  • Design and gamma sensitivity measurement of a novel dual-emitter vacuum Compton detector

    • A novel dual-emitter vacuum Compton detector (D-VCD) with higher gamma ray detecting efficiency is proposed. The emitters are made of Ta--Al clad metal. The gamma ray sensitivity is studied by Monte Carlo simulation using the MCNP code. A comparison between calculations and results measured by using the 1.25~MeV gamma ray of Co-60 is also performed. Experimental sensitivities for two sample D-VCDs with the same materials and structures are 1.92×10^-20 and 2.02×10^-20 C\cdotcm2/MeV separately, which are consistent with the simulation result of 1.98×10^-20 C\cdotcm2/MeV and are 4 times higher than that of VCD with a single Fe emitter. According to the simulation results, in a gamma energy range from 0.5 to 3 MeV, the maximum sensitivity variance for the D-VCD is less than 15%, and less than 5% in a range from 1 to 2 MeV in particular. The novel D-VCD is applicable to the detection of intense pulse gamma rays.
    • Article Text

    • loading

    Catalog

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return