Cite this article:
Le Zi-Chun, Liang Jing-Qiu, Dong Wen, Zhu Pei-Ping, Peng Liang-Qiang, Wang Wei-Biao, Huang Wan-Xia, Yuan Qing-Xi, Wang Jun-Yue. Focusing high-energy x-rays by a PMMA compound x-ray lens on Beijing synchrotron radiation facilityJ. Chin. Phys. B, 2007, 16(4): 984-988.
| Le Zi-Chun, Liang Jing-Qiu, Dong Wen, Zhu Pei-Ping, Peng Liang-Qiang, Wang Wei-Biao, Huang Wan-Xia, Yuan Qing-Xi, Wang Jun-Yue. Focusing high-energy x-rays by a PMMA compound x-ray lens on Beijing synchrotron radiation facilityJ. Chin. Phys. B, 2007, 16(4): 984-988. |
Focusing high-energy x-rays by a PMMA compound x-ray lens on Beijing synchrotron radiation facility
-
Abstract
The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays. -