Ultraviolet irradiation dosimeter based on persistent photoconductivity effect of ZnO |
Photoresponse characteristics of the ZnO MW device at 5 V bias. The 365 nm light of a mercury lamp is employed as the UV light source. (a) I–V curves as a function of light intensity. (b) Time-resolved photocurrent rise and decay with the illumination light switched on (at 0 s) and off (2400 s). (c) Repeatable response with UV light intensity of 37.6 μm/cm2. (d) Response spectrum of the ZnO MW device in semilogarithmic coordinates. The dependence of photocurrent (e) and photoconductive gain (f) of the ZnO MW device on UV light intensity. |