Nb-based Josephson parametric amplifier for superconducting qubit measurement*

Project supported by the Science Funds from the Ministry of Science and Technology of China (Grant Nos. 2015CB921104 and 2016YFA0300601), the National Natural Science Foundation of China (Grant Nos. 11674380 and 11874063), the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant Nos. XDB07010300 and XDB28000000), and the Key Research and Development Program of Guangdong Province, China (Grant No. 2018B030326001).

Su Fei-Fan1, 2, Wang Zi-Ting1, 2, Xu Hui-Kai1, 2, Zhao Shou-Kuan1, 2, Yan Hai-Sheng1, 2, Yang Zhao-Hua1, 2, Tian Ye1, 2, Zhao Shi-Ping1, 2, 3, †
       

The gain of the IMPA under the variations of the pumping power P and dc bias Ib (a) and under the variations of the pumping power P and the signal frequency ωs/2π (b). The color bars indicate the gains in unit dB. The left and right white dots in panel (a) indicate the two parameter sets for the results shown in Fig. 5. See text for the parameters used in the measurements.