An optimized ion trap geometry to measure quadrupole shifts of 171Yb+ clocks
Batra N1, 2, Sahoo B K3, De S1, 2, †,
(a) Our proposed electrode assembly of the end-cap trap with 2z0 = 0.7 mm, 2z2 ≈ 1.0 mm, 2r1 = 1 mm, 2r2 = 1.4 mm, 2r3 = 2 mm, θi = 10°, and θo = 45°. (b) Variation of the trap depth as a function of dc voltage U for a fixed radio-frequency ωrf and an ac voltage V.