中国物理B ›› 2022, Vol. 31 ›› Issue (5): 54212-054212.doi: 10.1088/1674-1056/ac3810

• • 上一篇    下一篇

Effect of the target positions on the rapid identification of aluminum alloys by using filament-induced breakdown spectroscopy combined with machine learning

Xiaoguang Li(李晓光)1, Xuetong Lu(陆雪童)2, Yong Zhang(张勇)1, Shaozhong Song(宋少忠)3,†, Zuoqiang Hao(郝作强)4, and Xun Gao(高勋)2,‡   

  1. 1 School of Electrical Information, Changchun Guanghua University, Changchun 130033, China;
    2 School of Physics, Changchun University of Technology, Changchun 130600, China;
    3 School of Information Engineering, Jilin Engineering Normal University, Changchun 130052, China;
    4 School of Physics and Electronic Sciences, Shandong Normal University, Jinan 250358, China
  • 收稿日期:2021-08-22 修回日期:2021-11-06 发布日期:2022-04-21
  • 通讯作者: Shaozhong Song,E-mail:songsz@jlenu.edu.cn;Xun Gao,E-mail:lasercust@163.com E-mail:songsz@jlenu.edu.cn;lasercust@163.com
  • 基金资助:
    Project supported by the Natural Science Foundation of Jilin Province,China (Grant No.2020122348JC).

Effect of the target positions on the rapid identification of aluminum alloys by using filament-induced breakdown spectroscopy combined with machine learning

Xiaoguang Li(李晓光)1, Xuetong Lu(陆雪童)2, Yong Zhang(张勇)1, Shaozhong Song(宋少忠)3,†, Zuoqiang Hao(郝作强)4, and Xun Gao(高勋)2,‡   

  1. 1 School of Electrical Information, Changchun Guanghua University, Changchun 130033, China;
    2 School of Physics, Changchun University of Technology, Changchun 130600, China;
    3 School of Information Engineering, Jilin Engineering Normal University, Changchun 130052, China;
    4 School of Physics and Electronic Sciences, Shandong Normal University, Jinan 250358, China
  • Received:2021-08-22 Revised:2021-11-06 Published:2022-04-21
  • Contact: Shaozhong Song,E-mail:songsz@jlenu.edu.cn;Xun Gao,E-mail:lasercust@163.com E-mail:songsz@jlenu.edu.cn;lasercust@163.com
  • About author:2021-11-10
  • Supported by:
    Project supported by the Natural Science Foundation of Jilin Province,China (Grant No.2020122348JC).

摘要: Filament-induced breakdown spectroscopy (FIBS) combined with machine learning algorithms was used to identify five aluminum alloys. To study the effect of the distance between focusing lens and target surface on the identification accuracy of aluminum alloys, principal component analysis (PCA) combined with support vector machine (SVM) and K-nearest neighbor (KNN) was used. The intensity and intensity ratio of fifteen lines of six elements (Fe, Si, Mg, Cu, Zn, and Mn) in the FIBS spectrum were selected. The distances between the focusing lens and the target surface in the pre-filament, filament, and post-filament were 958 mm, 976 mm, and 1000 mm, respectively. The source data set was fifteen spectral line intensity ratios, and the cumulative interpretation rates of PC1, PC2, and PC3 were 97.22%, 98.17%, and 95.31%, respectively. The first three PCs obtained by PCA were the input variables of SVM and KNN. The identification accuracy of the different positions of focusing lens and target surface was obtained, and the identification accuracy of SVM and KNN in the filament was 100% and 90%, respectively. The source data set of the filament was obtained by PCA for the first three PCs, which were randomly selected as the training set and test set of SVM and KNN in 3:2. The identification accuracy of SVM and KNN was 97.5% and 92.5%, respectively. The research results can provide a reference for the identification of aluminum alloys by FIBS.

关键词: filament-induced breakdown spectroscopy (FIBS), principal component analysis (PCA), support vector machine (SVM), K-nearest neighbor (KNN), aluminum alloys identification

Abstract: Filament-induced breakdown spectroscopy (FIBS) combined with machine learning algorithms was used to identify five aluminum alloys. To study the effect of the distance between focusing lens and target surface on the identification accuracy of aluminum alloys, principal component analysis (PCA) combined with support vector machine (SVM) and K-nearest neighbor (KNN) was used. The intensity and intensity ratio of fifteen lines of six elements (Fe, Si, Mg, Cu, Zn, and Mn) in the FIBS spectrum were selected. The distances between the focusing lens and the target surface in the pre-filament, filament, and post-filament were 958 mm, 976 mm, and 1000 mm, respectively. The source data set was fifteen spectral line intensity ratios, and the cumulative interpretation rates of PC1, PC2, and PC3 were 97.22%, 98.17%, and 95.31%, respectively. The first three PCs obtained by PCA were the input variables of SVM and KNN. The identification accuracy of the different positions of focusing lens and target surface was obtained, and the identification accuracy of SVM and KNN in the filament was 100% and 90%, respectively. The source data set of the filament was obtained by PCA for the first three PCs, which were randomly selected as the training set and test set of SVM and KNN in 3:2. The identification accuracy of SVM and KNN was 97.5% and 92.5%, respectively. The research results can provide a reference for the identification of aluminum alloys by FIBS.

Key words: filament-induced breakdown spectroscopy (FIBS), principal component analysis (PCA), support vector machine (SVM), K-nearest neighbor (KNN), aluminum alloys identification

中图分类号:  (Laser spectroscopy)

  • 42.62.Fi
52.38.Hb (Self-focussing, channeling, and filamentation in plasmas)