Modulation transfer spectroscopy based on acousto-optic modulator with zero frequency shift

Chen-Fei Wu(吴晨菲), Xue-Shu Yan(颜学术), Li-Xun Wei(卫立勋), Pei Ma(马沛), Jian-Hui Tu(涂建辉), Jian-Wei Zhang(张建伟), Li-Jun Wang(王力军)   

  1. 1 Department of Physics, Tsinghua University, Beijing 100084, China;
    2 State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China;
    3 Department of Precision Instruments, Tsinghua University, Beijing 100084, China;
    4 National Key Laboratory of Science and Technology on Vacuum Technology and Physics, Lanzhou Institute of Physics, Lanzhou 730000, China
  • 收稿日期:2018-06-13 修回日期:2018-07-31 出版日期:2018-11-05 发布日期:2018-11-05
  • 通讯作者: Jian-Wei Zhang, Jian-Wei Zhang E-mail:zhangjw@tsinghua.edu.cn;lwan@tsinghua.edu.cn
  • 基金资助:

    Project supported by the National Key Research and Development Program of China (Grant No. 2016YFA0302101), the Foundation of China Academy of Space Technology, and the Initiative Program of State Key Laboratory of Precision Measurement Technology and Instruments, China.

Modulation transfer spectroscopy based on acousto-optic modulator with zero frequency shift

Chen-Fei Wu(吴晨菲)1,2, Xue-Shu Yan(颜学术)2,3, Li-Xun Wei(卫立勋)4, Pei Ma(马沛)4, Jian-Hui Tu(涂建辉)4, Jian-Wei Zhang(张建伟)2,3, Li-Jun Wang(王力军)1,2,3   

  1. 1 Department of Physics, Tsinghua University, Beijing 100084, China;
    2 State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China;
    3 Department of Precision Instruments, Tsinghua University, Beijing 100084, China;
    4 National Key Laboratory of Science and Technology on Vacuum Technology and Physics, Lanzhou Institute of Physics, Lanzhou 730000, China
  • Received:2018-06-13 Revised:2018-07-31 Online:2018-11-05 Published:2018-11-05
  • Contact: Jian-Wei Zhang, Jian-Wei Zhang E-mail:zhangjw@tsinghua.edu.cn;lwan@tsinghua.edu.cn
  • Supported by:

    Project supported by the National Key Research and Development Program of China (Grant No. 2016YFA0302101), the Foundation of China Academy of Space Technology, and the Initiative Program of State Key Laboratory of Precision Measurement Technology and Instruments, China.

摘要:

We present a modulation transfer spectroscopy (MTS) configuration based on an acousto-optic modulator by using a variant of the typical double pass structure. One beam is modulated by using an acousto-optic modulator in opposite diffraction order to cancel the carrier frequency shift and produce a modulated pump beam. The line shape performance is investigated theoretically and experimentally. Laser frequency stabilization of the proposed configuration is demonstrated for the 133Cs|62S1/2, F=4> →|62 P3/2, F'=5> transition. The Allan deviations, which are measured by using beat note signals and the three-cornered hat method, are 3.6×10-11 in an integration time of 100 s and approximately 4×10-11 in a longer integration time.

关键词: modulation transfer spectroscopy, laser stabilization

Abstract:

We present a modulation transfer spectroscopy (MTS) configuration based on an acousto-optic modulator by using a variant of the typical double pass structure. One beam is modulated by using an acousto-optic modulator in opposite diffraction order to cancel the carrier frequency shift and produce a modulated pump beam. The line shape performance is investigated theoretically and experimentally. Laser frequency stabilization of the proposed configuration is demonstrated for the 133Cs|62S1/2, F=4> →|62 P3/2, F'=5> transition. The Allan deviations, which are measured by using beat note signals and the three-cornered hat method, are 3.6×10-11 in an integration time of 100 s and approximately 4×10-11 in a longer integration time.