Please wait a minute...
Chinese Physics, 2006, Vol. 15(2): 310-314    DOI: 10.1088/1009-1963/15/2/013
GENERAL Prev   Next  

An NLMS algorithm with optimized preparatory step-size parameters for SQUID-based MCG data processing

Li Zhuo (李倬), Chen Geng-Hua (陈庚华), Zhang Li-Hua (张利华), Yang Qian-Sheng (杨乾声), Feng Ji (冯稷)
Beijing National Laboratory for Condensed Matter Physics, Institute of Physics,Chinese Academy of Sciences, Beijing 100080, China
Abstract  We present a new least-mean-square algorithm of adaptive filtering to improve the signal to noise ratio for magnetocardiography data collected with high-temperature SQUID-based magnetometers. By frequently adjusting the adaptive parameter $\alpha $ to systematic optimum values in the course of the programmed procedure, the convergence is accelerated with a highest speed and the minimum steady-state error is obtained simultaneously. This algorithm may be applied to eliminate other non-steady relevant noises as well.
Keywords:  magnetocardiography      optimal step size  
Received:  30 May 2005      Revised:  18 October 2005      Accepted manuscript online: 
PACS:  87.80.-y (Biophysical techniques (research methods))  
  87.19.Hh (Cardiac dynamics)  
  47.63.Cb (Blood flow in cardiovascular system)  
  02.70.Rr (General statistical methods)  
Fund: Project supported by the Major Program for the Fundamental Research of the Chinese Academy of Sciences, China(Grant No KJCX2-W4) and the National High Technology Research and Development Program of China (Grant No 2002AA306412).

Cite this article: 

Li Zhuo (李倬), Chen Geng-Hua (陈庚华), Zhang Li-Hua (张利华), Yang Qian-Sheng (杨乾声), Feng Ji (冯稷) An NLMS algorithm with optimized preparatory step-size parameters for SQUID-based MCG data processing 2006 Chinese Physics 15 310

[1] Measurement of T wave in magnetocardiography using tunnel magnetoresistance sensor
Zhihong Lu(陆知宏), Shuai Ji(纪帅), and Jianzhong Yang(杨建中). Chin. Phys. B, 2023, 32(2): 020703.
[2] Residual field suppression for magnetocardiography measurement inside a thin magnetically shielded room using bi-planar coil
Kang Yang(杨康), Hong-Wei Zhang(张宏伟), Qian-Nian Zhang(张千年),Jun-Jun Zha(查君君), and Deng-Chao Huang(黄登朝). Chin. Phys. B, 2022, 31(7): 070701.
[3] A synthetic optically pumped gradiometer for magnetocardiography measurements
Shu-Lin Zhang(张树林), Ning Cao(曹宁). Chin. Phys. B, 2020, 29(4): 040702.
[4] Low-Tc direct current superconducting quantum interference device magnetometer-based 36-channel magnetocardiography system in a magnetically shielded room
Qiu Yang (邱阳), Li Hua (李华), Zhang Shu-Lin (张树林), Wang Yong-Liang (王永良), Kong Xiang-Yan (孔祥燕), Zhang Chao-Xiang (张朝祥), Zhang Yong-Sheng (张永升), Xu Xiao-Feng (徐小峰), Yang Kang (杨康), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2015, 24(7): 078501.
[5] Baseline optimization of SQUID gradiometer for magnetocardiography
Li Hua (李华), Zhang Shu-Lin (张树林), Qiu Yang (邱阳), Zhang Yong-Sheng (张永升), Zhang Chao-Xiang (张朝祥), Kong Xiang-Yan (孔祥燕), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2015, 24(2): 028501.
[6] A SQUID gradiometer module with large junction shunt resistors
Qiu Yang (邱阳), Liu Chao (刘超), Zhang Shu-Lin (张树林), Zhang Guo-Feng (张国峰), Wang Yong-Liang (王永良), Li Hua (李华), Zeng Jia (曾佳), Kong Xiang-Yan (孔祥燕), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2014, 23(8): 088503.
[7] Cardiac electrical activity imaging of patients with CRBBB or CLBBB in magnetocardiography
Zhu Jun-Jie (朱俊杰), Jiang Shi-Qin (蒋式勤), Wang Wei-Yuan (王伟远), Zhao Chen (赵晨), Wu Yan-Hua (吴燕华), Luo Ming (罗明), Quan Wei-Wei (权薇薇). Chin. Phys. B, 2014, 23(4): 048702.
[8] Multichannel fetal magnetocardiography using SQUID bootstrap circuit
Zhang Shu-Lin (张树林), Zhang Guo-Feng (张国峰), Wang Yong-Liang (王永良), Liu Ming (刘明), Li Hua (李华), Qiu Yang (邱阳), Zeng Jia (曾佳), Kong Xiang-Yan (孔祥燕), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2013, 22(12): 128501.
[9] Measurements, characteristics, and origin of new electromagnetic interference on magnetocardiographic measurements
Gu Hong-Fang (谷红芳),Cai Wen-Yan (蔡文艳),Wei Yu-Ke (魏玉科),Liu Zheng-Hao (刘政豪),Wang Qian (王倩),Wang Yue (王越),Dai Yuan-Dong (戴远东),Ma Ping (马平). Chin. Phys. B, 2012, 21(4): 040702.
[10] Characteristic parameters of electromagnetic signals from a human heart system
Liu Xin-Yuan(刘新元), Pei Liu-Qing(裴留庆), Wang Yin(王寅), Zhang Su-Ming(张素明), Gao Hong-Lei(高红蕾), and Dai Yuan-Dong(戴远东) . Chin. Phys. B, 2011, 20(4): 047401.
[11] Inverse computation for cardiac sources using single current dipole and current multipole models
Wang Qian(王倩),Ma Ping(马平),Lu Hong(陆宏), Tang Xue-Zheng(唐雪正),Hua Ning(华宁), and Tang Fa-Kuan(唐发宽) . Chin. Phys. B, 2009, 18(12): 5566-5574.
[12] Singular value decomposition with normalized period for magnetocaridiography signal processing
Li Zhuo(李倬), Liu Dang-Ting(刘当婷), Tian Ye(田野), Chen Geng-Hua(陈赓华), Zhang Li-Hua(张利华), Yang Qian-Sheng(杨乾声), and Feng Ji(冯稷). Chin. Phys. B, 2007, 16(10): 2913-2917.
[13] A digital filtering scheme for SQUID based magnetocardiography
Zhu Xue-Min (朱学敏), Ren Yu-Feng (任育峰), Yu Hong-Wei (于洪伟), Zhao Shi-Ping (赵士平), Chen Geng-Hua (陈赓华), Zhang Li-Hua (张利华), Yang Qian-Sheng (杨乾声). Chin. Phys. B, 2006, 15(1): 100-103.
[14] A complementary least-mean-square algorithm of adaptive filtering for SQUID based magnetocardiography
Li Zhuo (李倬), Chen Geng-Hua (陈赓华), Zhang Li-Hua (张利华), Yang Qian-Sheng (杨乾声), Feng Ji (冯稷). Chin. Phys. B, 2005, 14(6): 1095-1100.
[15] A normalized data-reusing least-mean-square algorithm of noise cancellation for magnetocardiography
Kong Xiang-Yan (孔祥燕), Wang Hui-Wu (王会武), Tian Ye (田野), Huang Xu-Guang (黄旭光), Zhang Li-Hua (张利华), Ren Yu-Feng (任育峰), Chen Geng-Hua (陈赓华), Yang Qian-Sheng (杨乾声). Chin. Phys. B, 2004, 13(11): 1820-1825.
No Suggested Reading articles found!