A normalized data-reusing least-mean-square algorithm of noise cancellation for magnetocardiography

Kong Xiang-Yan (孔祥燕), Wang Hui-Wu (王会武), Tian Ye (田野), Huang Xu-Guang (黄旭光), Zhang Li-Hua (张利华), Ren Yu-Feng (任育峰), Chen Geng-Hua (陈赓华), Yang Qian-Sheng (杨乾声)
Institute of Physics, Chinese Academy of Sciences, Beijing 100080, China
Abstract  An adaptive filter based on Data-Reusing Least-Mean-Square algorithm has been proposed and applied in magnetocardiography (MCG) to suppress ambient noise. Numerical simulation studies indicate that the adaptive filter is a powerful noise suppresser for correlated interferences, especially for those with amplitude changing and time delay. Also the filter has a wide frequency bandwidth. With this filter, the signal-to-noise ratio of an MCG is improved to the intrinsic noise level. The periodic average method for further improvement of the noise level in MCG is also discussed.
Keywords:  magnetocardiography      noise suppression  
Received:  16 April 2004      Revised:  08 June 2004      Accepted manuscript online: 
PACS:  87.19.Hh (Cardiac dynamics)  
  84.30.Vn (Filters)  
  84.40.Ua (Telecommunications: signal transmission and processing; communication satellites)  
  02.60.-x (Numerical approximation and analysis)  
  02.70.Rr (General statistical methods)  
Fund: Project supported by Chinese Academy of Sciences (Grant No KJCX2-W4) and the Ministry of Science and Technology of China (Grant No 2002AA306412 and NKBRSF-G1999064609).

Cite this article: 

Kong Xiang-Yan (孔祥燕), Wang Hui-Wu (王会武), Tian Ye (田野), Huang Xu-Guang (黄旭光), Zhang Li-Hua (张利华), Ren Yu-Feng (任育峰), Chen Geng-Hua (陈赓华), Yang Qian-Sheng (杨乾声) A normalized data-reusing least-mean-square algorithm of noise cancellation for magnetocardiography 2004 Chinese Physics 13 1820

[1] Precision measurement and suppression of low-frequency noise in a current source with double-resonance alignment magnetometers
Jintao Zheng(郑锦韬), Yang Zhang(张洋), Zaiyang Yu(鱼在洋), Zhiqiang Xiong(熊志强), Hui Luo(罗晖), and Zhiguo Wang(汪之国). Chin. Phys. B, 2023, 32(4): 040601.
[2] Measurement of T wave in magnetocardiography using tunnel magnetoresistance sensor
Zhihong Lu(陆知宏), Shuai Ji(纪帅), and Jianzhong Yang(杨建中). Chin. Phys. B, 2023, 32(2): 020703.
[3] Residual field suppression for magnetocardiography measurement inside a thin magnetically shielded room using bi-planar coil
Kang Yang(杨康), Hong-Wei Zhang(张宏伟), Qian-Nian Zhang(张千年),Jun-Jun Zha(查君君), and Deng-Chao Huang(黄登朝). Chin. Phys. B, 2022, 31(7): 070701.
[4] A synthetic optically pumped gradiometer for magnetocardiography measurements
Shu-Lin Zhang(张树林), Ning Cao(曹宁). Chin. Phys. B, 2020, 29(4): 040702.
[5] Stable continuous-wave single-frequency intracavity frequency-doubled laser with intensity noise suppressed in audio frequency region
Ying-Hao Gao(高英豪), Yuan-Ji Li(李渊骥), Jin-Xia Feng(冯晋霞), Kuan-Shou Zhang(张宽收). Chin. Phys. B, 2019, 28(9): 094204.
[6] Low-Tc direct current superconducting quantum interference device magnetometer-based 36-channel magnetocardiography system in a magnetically shielded room
Qiu Yang (邱阳), Li Hua (李华), Zhang Shu-Lin (张树林), Wang Yong-Liang (王永良), Kong Xiang-Yan (孔祥燕), Zhang Chao-Xiang (张朝祥), Zhang Yong-Sheng (张永升), Xu Xiao-Feng (徐小峰), Yang Kang (杨康), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2015, 24(7): 078501.
[7] Baseline optimization of SQUID gradiometer for magnetocardiography
Li Hua (李华), Zhang Shu-Lin (张树林), Qiu Yang (邱阳), Zhang Yong-Sheng (张永升), Zhang Chao-Xiang (张朝祥), Kong Xiang-Yan (孔祥燕), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2015, 24(2): 028501.
[8] A SQUID gradiometer module with large junction shunt resistors
Qiu Yang (邱阳), Liu Chao (刘超), Zhang Shu-Lin (张树林), Zhang Guo-Feng (张国峰), Wang Yong-Liang (王永良), Li Hua (李华), Zeng Jia (曾佳), Kong Xiang-Yan (孔祥燕), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2014, 23(8): 088503.
[9] Cardiac electrical activity imaging of patients with CRBBB or CLBBB in magnetocardiography
Zhu Jun-Jie (朱俊杰), Jiang Shi-Qin (蒋式勤), Wang Wei-Yuan (王伟远), Zhao Chen (赵晨), Wu Yan-Hua (吴燕华), Luo Ming (罗明), Quan Wei-Wei (权薇薇). Chin. Phys. B, 2014, 23(4): 048702.
[10] Multichannel fetal magnetocardiography using SQUID bootstrap circuit
Zhang Shu-Lin (张树林), Zhang Guo-Feng (张国峰), Wang Yong-Liang (王永良), Liu Ming (刘明), Li Hua (李华), Qiu Yang (邱阳), Zeng Jia (曾佳), Kong Xiang-Yan (孔祥燕), Xie Xiao-Ming (谢晓明). Chin. Phys. B, 2013, 22(12): 128501.
[11] Measurements, characteristics, and origin of new electromagnetic interference on magnetocardiographic measurements
Gu Hong-Fang (谷红芳),Cai Wen-Yan (蔡文艳),Wei Yu-Ke (魏玉科),Liu Zheng-Hao (刘政豪),Wang Qian (王倩),Wang Yue (王越),Dai Yuan-Dong (戴远东),Ma Ping (马平). Chin. Phys. B, 2012, 21(4): 040702.
[12] Characteristic parameters of electromagnetic signals from a human heart system
Liu Xin-Yuan(刘新元), Pei Liu-Qing(裴留庆), Wang Yin(王寅), Zhang Su-Ming(张素明), Gao Hong-Lei(高红蕾), and Dai Yuan-Dong(戴远东) . Chin. Phys. B, 2011, 20(4): 047401.
[13] Inverse computation for cardiac sources using single current dipole and current multipole models
Wang Qian(王倩),Ma Ping(马平),Lu Hong(陆宏), Tang Xue-Zheng(唐雪正),Hua Ning(华宁), and Tang Fa-Kuan(唐发宽) . Chin. Phys. B, 2009, 18(12): 5566-5574.
[14] Singular value decomposition with normalized period for magnetocaridiography signal processing
Li Zhuo(李倬), Liu Dang-Ting(刘当婷), Tian Ye(田野), Chen Geng-Hua(陈赓华), Zhang Li-Hua(张利华), Yang Qian-Sheng(杨乾声), and Feng Ji(冯稷). Chin. Phys. B, 2007, 16(10): 2913-2917.
[15] An NLMS algorithm with optimized preparatory step-size parameters for SQUID-based MCG data processing
Li Zhuo (李倬), Chen Geng-Hua (陈庚华), Zhang Li-Hua (张利华), Yang Qian-Sheng (杨乾声), Feng Ji (冯稷). Chin. Phys. B, 2006, 15(2): 310-314.
No Suggested Reading articles found!